Product specifications

Page 18 AD-4329A Weighing Indicator
5.3. Weighing Range Function
The weighing range function can select "single range", "dual range" and "triple range".
Specify each weighing interval (division) for the multi-interval instrument. Each
weighing interval is displayed according to a net value or gross value.
Caution Using a single range, it is not necessary to perform this function.
Perform the zero and span calibration after this function.
Example 1 The gross display.
Specified parameters:
First range Range = 20.00kg, division 0.01kg
Second range Range = 50.00kg, division 0.02kg
Third range Range = 100.00kg (maximum capacity), division 0.1kg
Display
0kg to 20kg : The first range, division 0.01kg.
20kg to 50kg : The second range, division 0.02kg.
50kg to 100kg : The third range, division 0.1kg.
Example 2 The net display using a 40kg tare value.
Specified parameters:
The same parameters as example 1.
Display
-40kg to -20kg : The second range, division 0.02kg.
-20kg to 20kg : The first range, division 0.01kg.
20kg to 50kg : The second range, division 0.02kg.
50kg to 60kg : The third range, division 0.1kg.
5.3. Weighing Range Function