Digital Blood Pressure Monitor Model UA-854 Instruction Manual Original Manuel d’instructions Traduction Manual de Instrucciones Traducción Manuale di Istruzioni Traduzione Bedienungsanleitung Übersetzung 使用手冊 翻譯 1WMPD4001741D
Contents Dear Customers .................................................................................... 1 Preliminary Remarks.............................................................................. 1 Precautions ........................................................................................... 2 Identification......................................................................................... 3 Symbols .................................................................................
Precautions Precision components are used in the construction of this device. Extremes in temperature, humidity, direct sunlight, shock or dust should be avoided. Clean the device and cuff with a dry, soft cloth or a cloth dampened with water and a neutral detergent. Never use alcohol, benzene, thinner or other harsh chemicals to clean the device or cuff. Avoid tightly folding the cuff or storing the hose tightly twisted for long periods, as such treatment may shorten the life of the components.
Identification AM Button PM Button MEMORY Button Display Air Connector Plug Arm Cuff START Button Air Socket Air Hose (Orange illumination during the AM) (Blue illumination during the PM) Battery Compartment 1.5V Batteries (R6P, LR6 or AA) DC Jack Part of Display MEMORY Clock display Day Time Temperature Battery Cover WHO Classification Indicator and Pressure Bar Indicator Battery Indicator Alarm ON/OFF mark Heart Mark English 3 Systolic Pressure Diastolic Pressure Pulse Rate I.H.B.
Symbols Symbols Function / Meaning Recommended Action Standby and Turn the device on. Battery installation guide Direct current SN Serial number 2007 Date of manufacture Type BF: Device, cuff and tubing are designed to provide special protection against electrical shocks. The indicator that appears while measurement is Measurement is in progress. in progress. It blinks when the pulse is detected. Remain as still as possible. Irregular Heartbeat indicator. (I.H.B.
Operation Mode 1. Normal Measurement With Storing Data Press the START button. Blood pressure is measured and data is stored within the device. The device can store the last 90 sets of data in memory. M 2. Recalling The Data Press the MEMORY button to recall the data. The average data of all the measurements is displayed, as indicated in the figure at the right. Then, each time the MEMORY button is pressed, the memory data is displayed from the most recent.
Using The Monitor Installing / Changing The Batteries 1. Slide the battery cover to open it. 2. Remove the used batteries and insert new batteries into the battery compartment as shown, taking care that the polarities (+) and (-) are correct. 3. Slide the battery cover to close it. Use only R6P, LR6 or AA batteries. Step 2 Step 1 Step 3 CAUTION Insert the batteries as shown in the battery compartment. If installed incorrectly, the device will not work.
Using The Monitor Adjusting The Built-in Clock Press and hold Adjust the clock prior to use. 1. Press and hold the AM button until the year starts blinking. 2. Select the year using the PM button. Press the AM button to set the current year and move to month/day selection. The date can be set anywhere between the years 2006 and 2056. 3. Select the month using the PM button. Press the AM button to set the current month and move to day selection. 4. Select the day using the PM button.
Using The Monitor Alarm ON/OFF Mark On The Display When the alarm is on, a “ ” appears on the LCD. To turn the alarm off, simply press the AM button once. The alarm will sound for 1 minute. To stop the alarm sound, press any button once. Selecting The Correct Cuff Size Using the correct cuff size is important for an accurate reading. If the cuff is not the proper size, the reading may yield an incorrect blood pressure value. The arm size is printed on each cuff. The arm cuff is a consumable.
Using The Monitor How To Take Proper Measurements For the most accurate blood pressure measurement: Sit comfortably on a chair. Rest your arm on the table. Do not cross your legs. Keep your feet on the floor and straighten your back. Relax for about five to ten minutes before measurement. Place the center of the cuff at the same height as your heart. Remain still and keep quiet during measurement. Do not measure immediately after physical exercise or a bath.
Measurements Model UA-854 is designed to detect the pulse and to inflate the cuff to a systolic pressure level automatically. If your systolic pressure is expected to exceed 230 mmHg, read "Measurement With The Desired Systolic Pressure" on the next page. Normal Measurement 1. Place the cuff on the arm (preferably the left arm). Sit quietly during measurement. 2. Press the START button. The START button illuminates in orange in the morning (AM) and blue in the afternoon (PM).
Measurements Measurement With The Desired Systolic Pressure If your systolic pressure is expected to exceed 230 mmHg, use this procedure. 1. Place the cuff on the arm (preferably the left arm). 2. Press and hold the START button until a number about 30 to 40 mmHg higher than your expected systolic pressure appears. 3. Release the START button to start measurement, when the desired number is reached. Then continue to measure your blood pressure as described on the previous page.
Recalling Memory Data Note: This device stores the last 90 measurements in memory. Clock display 1. Press the MEMORY button. The average data of all the measurements and the number of data are displayed. M Averaged systolic Averaged diastolic Number of data Average of all the data Press 2. Then, each time the MEMORY button is pressed, the memory data is displayed from the most recent. M Systolic Diastolic Pulse rate Most recent data: Displays alternately every 3 seconds M M 3.
Recalling Memory Data 4. Press the following key to recall various data when the average data of all the measurements is displayed. AM button To recall the average data during the AM. The START button illuminates in orange. Then, each time the AM button is pressed, the memory data taken during the AM is displayed from the most recent. After the last data is displayed, the display returns to the clock display PM button To recall the average data during the PM. The START button illuminates in blue.
What Is An Irregular Heartbeat Model UA-854 blood pressure monitor provides a blood pressure and pulse rate measurement even when an irregular heartbeat occurs. An irregular heartbeat is defined as a heartbeat that varies by 25% from the average of all heartbeats during the blood pressure measurement. It is important that you be relaxed, remain still and do not talk during measurements. Note: We recommend contacting your physician if you see this indicator frequently.
About Blood Pressure What Is Blood Pressure? Blood pressure is the force exerted by blood against the walls of the arteries. Systolic pressure occurs when the heart contracts. Diastolic pressure occurs when the heart expands. Blood pressure is measured in millimeters of mercury (mmHg). One's natural blood pressure is represented by the fundamental pressure, which is measured first thing in the morning while one is still at rest and before eating.
Blood Pressure Regular readings give a more comprehensive blood pressure history. Be sure to note the date and time when recording your blood pressure. Consult your doctor to interpret your blood pressure data. Typical fluctuation within a day (Measured every five minutes) Systolic Diastolic Sleep Troubleshooting Problem Possible Reason Recommended Action Replace all batteries with new Nothing Batteries are drained. ones.
Maintenance Do not open the device. It uses delicate electrical components and an intricate air unit that could be damaged. If you cannot fix the problem using the troubleshooting instructions, request service from your dealer or from the A&D service group. The A&D service group will provide technical information, spare parts and units to authorized dealers. The device was designed and manufactured for a long service life.
Dimensions Approx. 150 [W] x 156 [H] x 126 [D] mm Weight Approx. 500 g, excluding the batteries Applied part Cuff Type BF Useful life Device: 5 years (when used six times a day) Cuff: 2 years (when used six times a day) Accessory AC adapter The adapter is to connect the blood pressure monitor to a power source at home. TB-233 Please contact your local A&D dealer for purchasing. The AC adapter is required to be inspected or replaced periodically.
1-243 Asahi , Kitamoto-shi, Saitama 364-8585, JAPAN Telephone: [81] (48) 593-1111 Fax: [81] (48) 593-1119 A&D INSTRUMENTS LIMITED Unit 24/26 Blacklands Way, Abingdon Business Park, Abingdon, Oxfordshire OX14 1DY United Kingdom Telephone: [44] (1235) 550420 Fax: [44] (1235) 550485 A&D ENGINEERING, INC. 1756 Automation Parkway, San Jose, California 95131, U.S.A.