7. COUNTING MODE
Determines a unit weight (the weight of one piece) from a known sample quantity, and
calculates how many pieces are on the weighing pan using the unit weight.
The unit weight is maintained even if the power is turned OFF.
1. Tap the UNITS switch to se lect "pcs".("pcs" = pieces)
2. Tap the SAMPLE switch to enter the sample
unit weight storing mode. The numerical value on
the left indicates the number of samples.
3. Tapping the SAMPLE switch allows you to
change the number of samples in the order
5 Æ 10 Æ 20 Æ 50 Æ 100 Æ ESC Æ 5.
• By tapping the UNITS switch when
is displayed, the scale exits the sample unit
weight storing mode to the count display.
4. When "-" appears at the right side of the number of
samples, tap the switch to zero the scale.
If necessary, place a container on the weighing
pan, and tap the TARE switch. Confirm that the
right side of the number of samples shows zero.
5. Place the correct number of samples on the
weighing pan or in the container.
6. Confirm that the STABLE indicator is turned on.
Tap the UNITS switch to calculate and store
the unit weight. Remove the samples. The scale
is set to count objects with this unit weight.
The total weight of samples should be more than
shown below, regardless of the number of samples.
SJ-3000WP: 2.5 g
SJ-6000WP: 5 g
SJ-15KWP: 12.5 g
SJ-30KWP: 25 g
If not, the display shows
and returns
to the display of step 5. Increase the number of
samples (step 3) and try again.
7. Place the objects to be counted on the weighing pan.
Confirm
zero
Number o
f
samples
Samples
Weighing pan
Container
Tap
Tap
Tap
Tap
Tap