Setup guide

6-22
EPC Connecting Guide
3. Only if Powerconsole is used
Establish the connection between the workstation and CS/2600 on the serial port J0
using the cu command on the PowerConsole side (see step 1).
4. Switch the CS/2600 to monitor mode:
make a hardware reset (button on the left side of the CS/2600) as described in the
CS/2600 Installation Guide.
5. Wait few seconds, then press <Enter> two–three times during regular interval of 1
second, the following prompt must be displayed:
3Com Corporation CS/2600 Series Monitor
>
6. Make a copy of the original floppy diskette to a new diskette
as described in the CS/2600 Installation Guide. (for this, use the command ”co”)
7. Take away the original diskette and use the new one.
8. Key in the command (after >):
> fc <Enter>
The following menu will be displayed:
Firmware Configuration Utility Commands:
C – Change parameters
D – Display parameters
Esc – Exit to monitor
9. Choose the menu Change parameters, by keying:
C <Enter>
10.Modify the following parameters as:
5. Monitor Disabled
6. Initial Boot source Local Floppy
A. Boot protocol TFTP Boot
B. IP/TFTP parameters
Refer to the CS/2600 Installation Guide to see how to modify these values.
11.IP/TFTP parameters Configuration
Select the menu B that appears once TFTP Boot protocol has been selected for menu A:
setup the ”Adr discover protocol” with Local Information
setup the ”Client Ip address” with the Ethernet address chosen for the CS2600 server
(@IPCS/2600): for example 120.184.33.10
setup the ”Gateway address” with for example 120.184.33.10, if necessary
(customers LAN)
setup the ”Subnet mask value” with the subnet mask of the client LAN network,
for example: 255.255.255.0
12.Exit from all the menus with <Esc> till the prompt >
13.Reset the CS/2600 server softly.
(Push the reset switch in the front panel).
14.At the end of self testing phase
(Self test and boot state leds go off),
Wait at least 2 minutes (the led of the floppy driver turns off),