Setup guide

10-70
EPC Connecting Guide
HA DLT7000
(DE – 68mD)
Y cable / adapter
6m Cable / adapter
[CKTG070–0000
CBLG157–1700
CKTG049–0000
CBLG157–1700
[CKTG070–0000
CBLG157–1700
DLT not shared
Cable for DLT7000
Cable for DLT4000
CBLG157–1700
CBLG158–1700
CBLG102–1700
CBLG152–1900
CBLG157–1700
CBLG158–1700
Case of the Shared Library
1. In addition to the Y–cable there is a terminator feed thru included in CKTF003 that
allows to plug the 68mD cable (CBLG157–1700) into the DLT4000 (50mD).
2. Before connecting the Y-cable to the SCSI board, make sure you don’t leave a
terminator on the SCSI board. Remove one, if any. This is the case for EPC1200
or EPC1200A nodes where you must remove the terminator (P/N 42G3326) form
the PCI Differential Ultra SCSI board (4-L – IBM FC 6207).
3. LXB 4000 and LXB 7000 are libraries that can be shared by two homogeneous
nodes with HA Netbackup application. The Master server or the Slave Server can
be redundant implementing hot standby or mutual recovery mode.
It is important to underline that HA Netbackup is not integrated in
ClusterAssistant.
Cabling Diagrams
Overall Diagram
Case of a Library not Shared
This configuration is an example of an EPC400 with a library attached to a node.
Figure 126. Overall Diagram – EPC400 with one library attached to a node (library not
shared).