Setup guide

10-16
EPC Connecting Guide
Cabling Instructions
The cabling instruction lines are generated by the ordering document.
The nodes are named by N1, N2, .. N8.
U1, U2, U3 designate the SSA units.
P1, P4, P5, P8, P9, P12, P13, P16 and so on designate the ports on an SSA cabinet.
An instruction line specifies (NiAj) on which adapter of which node a cable end has to be
plugged, and (UkPl) on which port of which SSA unit the other cable end must be
plugged.
The instruction lines allowing to cable the example of diagram SSACF01 are generated by
the ordering document as follows :
N1A1 – U1P5
U1P8 – N4A2
N4A1 – U1P9
U1P12 – N2A2
N2A1 – U1P13
U1P16 – N3A2
N3A1 – U1P1
U1P4 – N1A2
The line N2A1 – U1P13 means to plug a cable end on adapter A1 of node #2 and the
other cable end on port 13 of SSA cabinet (U1 as unit #1).