Setup guide
10-2
EPC Connecting Guide
SSA Disk Subsystem
You will find:
• MI List, on page 10-2.
• General Information, on page 10-2.
• Cabling Diagrams, on page 10-4.
• Cabling Instructions, on page 10-16.
• Optic Fibre Extender, on page 10-17.
MI List
Identificator
Description FRU
SSAG007–0000 SSA DISK SUBSYSTEM RACK w/ four 4.5 GB Disk Drives
SSAG009–0000 SSA DISK SUBSYSTEM RACK w/ four 9.1 GB Disk Drives
SSAG004–0000 SSA DISK SUBSYSTEM RACK
MSUG068–0000 4,5GB SSA DISK DRIVE MODULE
MSUG082–0000 9,1GB SSA DISK DRIVE MODULE
CKTG069–0000 SSA OPTIC FIBRE EXTENDER
CBLG162–1400 SSA SUBSYSTEM CABLE (2,5M)
CBLG162–1700 SSA SUBSYSTEM CABLE (5M)
CBLG162–1900 SSA SUBSYSTEM CABLE (10M)
CBLG163–1100 SSA LOOP TO LOOP CABLE (1M)
MSCU101–0000 6216 – SSA ENHANCED 4–PORT ADAPTER (TYPE 4–G)
MSCG021–0000 6214 – SSA 4–PORT ADAPTER (TYPE 4–D)
MSCG029–0000 6217 – SSA RAID ADAPTER (TYPE 4–I)
MSCG038–0000 6219 – MCA SSA 2-w JBOD & 1-w RAID ADAPTER (TYPE
4–M)
MSCG024–0000 6218 – PCI SSA 1-w JBOD & RAID ADAPTER (TYPE 4–J)
MSCG039-0000 6215 – SSA 4-PORT PCI Multi-Initiator/RAID EL ADAPTER
(TYPE 4–N)
MSCG036-0000 ditto but for EPC1200, EPC1200A
CMMG110-0000 6222 – SSA Fast/Write 4MB Cache Option Card
General Information
These components are used with the SSA model 020.
Use of internal bypass is allowed.
The cabling diagrams only deal with a single loop. For double loop, the physical connections
must be doubled. The second loop can be set up on the same adapter or on a second one,
in which case two adapters give a higher availability.
Disk mirroring can be implemented across two loops, through the standard features of the
AIX system. (Disks on a loop are mirrored to disks on the other loop).
Standard cable length is 10m (MI CBLG162-1900). When several cable types are part of the
configuration, start to use the larger cables and end with the shorter ones.