Product specifications
Page 90 AD-4402
8.6.
8.6.8.6.
8.6. RS
RSRS
RS-
--
-422/485 Interface of Option OP
422/485 Interface of Option OP422/485 Interface of Option OP
422/485 Interface of Option OP-
--
-03
0303
03
The RS-422/485 interface can use commands to control the indicator. The interface
can read weighing data or parameters or store parameters to the indicator.
The interface can connect a maximum of 32 units and a personal computer using a
communication cable.
The unit is specified by an address appended to the command.
RS-485 can use 2-wire or 4- wire.
The command and format are the same as the built-in RS-485.
Transmission system EIA RS-422 / 485,
Asynchronous, bi-directional, half-duplex
Data length 7 bits or 8 bits
Start bit 1 bit
Parity bit Odd, Even, not used
Stop bits 1 bit, 2 bits
Baud rate 600 bps, 1200 bps, 2400 bps, 4800 bps, 9600 bps, 19200
bps, 38400 bps(Jet stream mode)
Line RS-422: 4 wires
RS-485: 2 wires or 4 wires
Connection Max. 32 units
Character code ASCII code
Terminator CR, CR LF
Caution
Either option OP-03 or OP-04 can install
Connection
SD
A
Terminator switch
SDB
RD
A
RDB
SG
FG
AD-4402
OP-03 inside
3 RDA
4 RDB
5 SG
DE/RE
422/485
FG
1 SD
A
2 SDB
6 FG
TERMINATO
R
100Ω
SD
RD