Product specifications

AD-4402 Page 79
8.2.4.
8.2.4.8.2.4.
8.2.4. Genera
GeneraGenera
General Data Format
l Data Formatl Data Format
l Data Format
This format is used for the command mode and jet stream mode.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
R G R S 0 0 9 9 , 1 2 3 4 5 6 7 , 1 2 3 4 5 6 7 8 9
C
R
L
F
Header
Command is echoed. The echoed command is 4 characters
Code
Material code or recipe code number. The code is 4 characters
Weighing data
Data uses BCD code, is 7 figures and does not include a decimal point.
When data is negative, a minus sign is appended to the head.
System Monitor
Terminator
CR or CR + LF CR: 0Dh, LF: 0Ah
Header Code Weighing data
System Monitor
Terminator
2
0
: Stable
2
1
: Zero band
2
2
: Full
2
3
: Full flow
1 2 8 9 7 6 5 4 3
2
0
: Medium flow
2
1
: Dribble flow
2
2
: Over
2
3
: OK
2
0
: Discharge gate
2
1
: Batch finish
2
2
: Recipe finish
2
3
: Discharge finish
2
0
: Under
2
1
: Internal reservation
2
2
: Internal reservation
2
3
: Mixing
2
0
: Mixing finish
2
1
: Nozzle down
2
2
: Online
2
3
: During weighing sequence
2
0
: Internal reservation
2
1
: Weighing error
2
2
: Alarm 1
2
3
: Alarm 2
2
0
: Zero error
2
1
: Out of range
2
2
: Buzzer
2
3
: During tare
2
0
: Center of zero
2
1
: Gross display
2
2
: net display
2
3
: During hold
Internal reservation
Example: 2
3
2
2
2
1
2
0
1
0
1
0 = Ah
ASCII code = 3Ah.
Upper 4 bits are 3h always.