Product specifications

AD-4402 Page 57
7.3.12.
7.3.12.7.3.12.
7.3.12. Restart Sequences from Pause
Restart Sequences from Pause Restart Sequences from Pause
Restart Sequences from Pause
The restart input was used to start from the point that is stopped in the last sequence.
The control inputs of the function use the preset I/O terminals or OP-05 terminals that
select Restart.
The action of the function is as follows:
When it stopped Before the restart Action of the restart
During initial dribble flow Start from initial dribble flow
During initial medium flow Start from initial medium flow
During full flow Start from medium flow
During medium flow Start from dribble flow
During dribble flow
All gates are closed
Start from dribble flow
Waiting batch finish signal Waiting batch finish signal
During compensation Start from compensation
During nozzle operation Stopping the operation Start from nozzle operation
During mixing Stopping the mixing Start from the mixing
During discharge Stopping discharge Start from discharge
During recipe sequence According to above list According to above list