Product specifications
Page 42 AD-4402
7.3.2.
7.3.2.7.3.2.
7.3.2. Loss
LossLoss
Loss-
--
-in
inin
in-
--
-weigh
weighweigh
weigh of
of of
of the
the the
the Sequential
SequentialSequential
Sequential Mode
Mode Mode
Mode
Loss-in-weigh weighs the material discharged from the hopper.
Control gates (valves) can be used. (Full flow, medium flow and dribble flow)
Concerning Parameters of the Function
Selecting normal batching of built-in automatic program mode.
[5q f- 1] [1] Built-in automatic program mode
[Function] - [Function setting] - [Sequence] - [Basic] - [Weighing mode]
[5q f- 3] [0] Normal batch weighing
[Function] - [Function setting] - [Sequence] - [Basic] - [Loss-in-weigh]
Setting the display to zero automatically when starting the sequence.
[5q f-11]
[Function] - [Function setting] - [Sequence] - [Control] - [Batch start settings]
Switching normal batching and loss-in-weigh from the I/O interface.
[5q f- 3] [2] External exchange
Set an input terminal to switch the mode at the I/O interface. Material
can be supplied to the hopper with three gates (valves).
[Function] - [Function setting] - [Sequence] - [Basic] - [Loss-in-weigh]
Checking whether is there enough remaining weight for one batch weighing.
[5q f-55] [1] When the remaining weight is under the final weight + zero band, the
signal "zero band" is output.
[Function] - [Function setting] - [Sequence] - [Setpoint (Compared value)] -
[Add final value and zero band]
[5q f-56] [1] If this is set, when the hopper is filled fully, the signal "Full" is output.
[Function] - [Function setting] - [Sequence] - [Setpoint (Compared value)] -
[Add final value and full value]