Product specifications

AD-4402 Page 101
9.3.8.
9.3.8.9.3.8.
9.3.8. Testing the RS
Testing the RSTesting the RS
Testing the RS-
--
-232C Interface of OP
232C Interface of OP232C Interface of OP
232C Interface of OP-
--
-04
0404
04
When pressing the ENTER key each time, the test data "ST,GS,+0000000kg CR LF"
is output.
9.3.9.
9.3.9.9.3.9.
9.3.9. Testing the Parallel I/O of OP
Testing the Parallel I/O of OPTesting the Parallel I/O of OP
Testing the Parallel I/O of OP-
--
-05
0505
05
Test the output of the terminals. An active output of level "1" shifts for each terminal.
9.3.10.
9.3.10.9.3.10.
9.3.10. Testing the Analog Output of OP
Testing the Analog Output of OPTesting the Analog Output of OP
Testing the Analog Output of OP-
--
-07
0707
07
When pressing the 1 key, the output current is increased.
When pressing the 2 key, the output current is decreased.
Sent data
123kg
RNET
ST,GS,+0000000kg
←↓
0p-04 rcu and 5nd
Received data
Parity: p
Framing:
f
123kg
OP-05 0000000000000000
a16 a1
0001000000000000
b16 b1
Input terminal A1
Output terminal B1
96.27kg
OP-07
20 mA
Analog output