Error Messages
Configuration Errors
Error Description
ER.DAT There is no data being received by the unit.
ER.RX The baud rate/parity or stop bits are incorrect.
ER.ETX No ETX character was found in the data stream.
ER.FLD The data stream does not match any format.
ER.LEN The field to be displayed is longer than 6 digits.
Weighing Errors
(U-----) The weight is below the minimum allowable
weight reading.
(O-----) The weight is above the maximum allowable
weight reading.
(------) The weight being transmitted is invalid (as per
remote indicator).
Operating Errors
Code Error Description
E 0001 The power supply voltage is too low
E 0002 The power supply voltage is too high
E 0100 The digital setup information has been lost
E 0300 All setup information has been lost
E 0400 The factory information has been lost
E 0800 The EEPROM memory chip has failed
E 8000 The EPROM memory chip has failed
The āEā type error messages are in hexadecimal and are
additive (eg 0900 = 0800 + 0100).