Specifications
Table Of Contents
- Overview
- Configuration
- Configuration Profiles
- General Profile Settings
- Configuring Devices
- Activating Tag Actions
- Validation Constraints
- Audible Alert Sound Events
- Data Collection and Validation
- Importing and Exporting
- Tools
- Tag Actions
- Tag Action Manager
- Tag Action Settings and Commands
- Tip: the Replace command will import tag codes much faster than the Import command. Use the Import command only when appending a relatively small number of tag codes (less than 25k) to a tag action.
- Tip: the Delete All and Replace commands will generate a lot of empty space in the P3 database. We recommend running the Compact and Repair utility after running any of these commands to optimize the database.
- Tag Actions and Data Entry
- Digitizer Maps
- Searching Data
- Replacing Data Values
- Merging Tag Sessions
- Dot-Out Wizard
- Remove Dot-Outs
- Duplicate Viewer
- Validation Codes
- Database Maintenance
- Tag Actions
- Appendix
- Frequently Asked Questions
- Hardware Support
- Troubleshooting Common Tag Reader Problems
- Troubleshooting Common Digitizer Tablets Problems
- Digitizer Tablet Doesn't Register Pen Clicks
- WinTab Digitizer Tablet Won't Communicate with a PC
- ASCII Digitizer Tablet Won't Communicate with a PC via Serial Port
- Digitizer Tablet doesn't Communicate with P3
- Digitizer Tablet is Sending the Wrong Commands
- Digitizer Tablet is Sending Wrong Lengths
- Digitizer Tablet Hangs P3 when Connected via Baytech Multiport
- Operating the Destron 400 kHz Benchtop Tag Reader
- Configuring Calcomp Drawing Board III
- Index

P3 Help
18
WinTab Digitizer Tablets
WinTab digitizer tablets communicate to the application using an external device
driver. This tablet must be installed using the manufacturer's installation program
before it can be used with P3. This type of device cannot be connected to a multiport
controller. When a tag session is not currently open, this device may control the
mouse cursor.
Note: Only one WinTab device can be configured for a single profile.
Digitizer Tablet Property Settings
Both types of digitizer tablets have the following additional property settings:
Property Effect
Map Associates a digitizer map with this device.
Resolution
Divisor
This decimal number is used as a divisor to convert the x-
coordinate of a digitizer pen click into a length in
millimeters. ASCII tablet resolutions are usually specified
in lines-per-inch and this setting is used to divide lines-
per-inch into lines-per-millimeter. So, for example, if the
resolution is 2,540 lines-per-inch, setting the resolution
divisor to 10 would convert the x-coordinate into
millimeters (Hint: 254 millimeters per inch). WinTab
resolutions are vendor or model-specific. See the P3
Home Page web site for recommended divisor values.
Nose Stop
Extension
This number, in millimeters, is added to any length input
from the associated tablet device and is used to extend
the range of measure.
If this setting is set to a non-zero value, a "+" sign will
appear above the Length input field to indicate all lengths