Specifications
Table Of Contents
- Overview
- Configuration
- Configuration Profiles
- General Profile Settings
- Configuring Devices
- Activating Tag Actions
- Validation Constraints
- Audible Alert Sound Events
- Data Collection and Validation
- Importing and Exporting
- Tools
- Tag Actions
- Tag Action Manager
- Tag Action Settings and Commands
- Tip: the Replace command will import tag codes much faster than the Import command. Use the Import command only when appending a relatively small number of tag codes (less than 25k) to a tag action.
- Tip: the Delete All and Replace commands will generate a lot of empty space in the P3 database. We recommend running the Compact and Repair utility after running any of these commands to optimize the database.
- Tag Actions and Data Entry
- Digitizer Maps
- Searching Data
- Replacing Data Values
- Merging Tag Sessions
- Dot-Out Wizard
- Remove Dot-Outs
- Duplicate Viewer
- Validation Codes
- Database Maintenance
- Tag Actions
- Appendix
- Frequently Asked Questions
- Hardware Support
- Troubleshooting Common Tag Reader Problems
- Troubleshooting Common Digitizer Tablets Problems
- Digitizer Tablet Doesn't Register Pen Clicks
- WinTab Digitizer Tablet Won't Communicate with a PC
- ASCII Digitizer Tablet Won't Communicate with a PC via Serial Port
- Digitizer Tablet doesn't Communicate with P3
- Digitizer Tablet is Sending the Wrong Commands
- Digitizer Tablet is Sending Wrong Lengths
- Digitizer Tablet Hangs P3 when Connected via Baytech Multiport
- Operating the Destron 400 kHz Benchtop Tag Reader
- Configuring Calcomp Drawing Board III
- Index

P3 Help
16
Device Action
A device action is triggered when a tag code is received from a reader device. This is
useful for identifying a tag code scanned from a particular device (e.g. scanning for
recaptured fish). The user may want to be notified of such an event and an optional
comment can be placed on the current detail record. Additionally, an optional sound
event can be configured for this action in the profile's audible alert
profile settings.
The device Action tab becomes available when the user selects a reader device in the
Device Type setting
.
Note: Device actions are not allowed for tag readers connected to a Baytech
Multiport Controller.
Property Effect
Device Action
Enabled
Enables the action to trigger when a tag code is input
from the associated device.
Alert Message An optional message can be displayed to notify the user.
This message can be up to 255 characters long.
Species Run
and Rearing
Type
If this field is not empty, this comment will overwrite any
species run and rearing-type codes in the current detail
record, whether verbose or numeric
.
VRT If this field is not empty, this code will overwrite any
existing variable release time code in the current detail
record.
Additional
Positional
Any comments placed in this field will merge by position
with any existing Additional Positional Comments in the
current detail record.
Conditional
Comment
Any valid comment placed in this field will be uniquely
appended to any existing conditional comments in the
current detail record.
Text Comment Any comment placed in this field will be appended to any