Sq F—Weighing Sequence Functions
The SqF functions are available only for the mode specified in the note column and each mode name
is described as shown below. Not specified functions are available for all the weighting sequences.
Auto: Built-in automatic program mode
Batch: Batch-weighing mode
Loss: Loss-in-weight mode Nozzle: Nozzle controlled weighing mode
Note
Function #
Function name Range
Default
SqF-01 Selection of comparison weight 1
1 Internal count
2 Display count
Sq F-02 Automatic accumulation 0
0 No Automatic accumulation
1 Accumulates only acceptable
2 Accumulates all values
Sq F-03 Automatic free fall compensation 0
0
No automatic free fall compensation
Batch
1
Moving average of last four times
Sq F-04
Automatic free fall
effective width
0 - 9999999 0
Batch
Automatic free fall compensation is made if the measured weight is within the final +/-
automatic free fall effective width.
Sq F-05
Unstable Dribble
Flow Time
0.0 - 25.5 (sec.) 3.0
Auto
If Flow-time is shorter than the setting, the preset Free Fall is applied to the weighing instead of
the Auto-Free-Fall compensation.
Sq F-06 Overlimit/ underlimit operation 2
1
Customer programmed control mode
Auto
2
Synchronized with Batch Finish Output
Sq F-07 Stability at judgment 1
0
Not required
Auto
1
Required
Sq F-08
Maximum number of
supplementary flow
times
0 – 255 (times) 0
Auto
This is the number of how many times supplementary flow is done.
Sq F-09 Batch start wait timer 0.0 - 25.5 (sec.) 0.0
Auto
Sq F-10
Full-flow comparator
inhibitor timer
0.0 - 25.5 (sec.) 0.0
Auto
Sq F-11
Medium-flow
comparator inhibitor
timer
0.0 - 25.5 (sec.) 0.0
Auto
Sq F-12
Dribble-flow
comparator inhibitor
timer
0.0 - 25.5 (sec.) 0.0
Auto
Sq F-13 Judgment wait timer 0.1 - 25.5 (sec.) 0.1
Auto