Instruction manual
A
-3
General specifications
Structure
•
•
Anti explosion structure
Type: ExDBT5 (Inspection qualified number: “C1
3526”
Data backup
•
•
•
Zero point correction value, tare value, set point, accumulated weight
backup by a lithium battery (Appro
x. 10 years)
An alarm indicator lamp is turned on when the battery is running out.
Calibration data, and each function dat
a stored into the non-volatile
memory (EEPROM). (Up to 10,000 times)
Buzzer Approximately 90dB at a place 1 meter away.
Supply voltage
100 VAC +10%-15%, 50Hz60Hz
Power consumption 60 VA
Fuse 1A, time-lag type fuse
Operating temperature
& humidity
-5 to +40°C, 45 to 85%RH (non-con
densing)
Storage temperature &
humidity
-15 to 70°C, 45 ~ 85%RH
(non-condensing)
Weight (accessories not
included)
Approximately 26kg
Dimensions
300(W) X 380(H) X 199(D) mmSee {Dimensions} in det
ail
Options
RS-422/485 OP-03
RS-232C OP-04
Either OP-03 or OP-04 can be installed. Not both in one unit.
Analog
output
OP-07
Type Fitting cable diameter Fitting connector diameter
OP-10
HPN21(R 8)
up to 8 mm beyond 6 mm
OP-11 HPN21(R10)
up to 10 mm beyond 8 mm
OP-12 HPN21(R12)
up to 12 mm beyond 10 mm
G 1/2 (PF 1/2)
OP-13 HPN22(R14)
up to 14 mm beyond 12 mm
Conduit
fittings
OP-14 HPN22(R16)
up to 16 mm beyond 14 mm
G 3/4 (PF 3/4)
Stand OP-20
Accessories
•
•
•
Hexagonal wrench to open/close the case X 1
Hexagonal wrench to affix cables to conduit fittings X 1
Instruction manual (this book) X 1