Instruction manual

6-14
6-8 CALF-14=“5” Weighing Mode
(Nozzle controlled weighing mode)
Output signal Output condition
Zero band
Gross weight
Zero band
Full-flow Final -
Optional preliminary
Net weight
Medium-flow Final - Preliminary
Net weight
Dribble-flow Final - Free fall
Net weight
Over limit Final + Over limit < Net weight
Under limit Net weight < Final - Under limit
When an output condition is established, a relevant output terminal is turned on or off. “Full flow”, “Medium flow”,
and ”Dribble flow”: OFF, the other outputs: ON.
Once the full flow, medium flow, and dribble flow are turned off, they are not turned on until the next start of batching.
Over limit / Under limit is activated based on the net weight upon batch finish. (May be changed to customer
programmed control mode operation)
The zero band is a customer programmed control mode operation.
Weighing process
#
Process
#
Process
1
[ZERO] is pressed.
Gross weight becomes ”0”.
2
A container is placed on the weighing platform.
3
[TARE] is pressed
If SqF-26=”1”:
Tared at batch start automatically
Weight is tared at sequence # 4. Automatically.
Weight is tared.
Net weight becomes “0”.
4
The “Batch start” signal is input.
If SqF-26=”1”:
Tared at batch start automatically
Weight is tared at the “Batch start” input.
(Tare action is the same as [TARE].)
The “Batch start wait timer” will start 1 second (time
for visual inspection for the tare action) later.
The “Nozzle down” signal is turned on.
The “Batch start wait timer” starts.
9
(Continued)
In case of No supplementary flow
Supplementary flow is not made when;
If SqF-09”0” and judgement result is either
“Acceptable weight” or “Over limit”.
If SqF-09=”0”: No supplementary flow setting.
Net weight is judged and either “Over limit”,
“Acceptable weight”, or “Under limit” signal is
turned on based on judgement result.
The “Batch monitoring timer” is reset.
The net weight is accumulated automatically.
The data is output from the interface set for auto
print.
Weighing process leads to sequence #13.
In case that supplementary flow is made
Supplementary flow is made when;
If SqF-09”0” and judgement result is
“Under limit”.
The “Nozzle down “ signal is turned on.
The “Batch monitoring timer” starts.
5
The “Batch start wait timer” completes the set time.
“Full-flow”, “Medium-flow” and “Dribble-flow”
output signals are turned on.
The “Full-flow comparator inhibitor timer” and
“Batch monitoring timer” start.
10
The “Batch monitoring timer” completes the set
time.
The “Dribble-flow“ signal is turned off.
The “Supplementary flow open timer” starts.
6
Net weight reaches the weight of “Final” –“Optional
preliminary” or more.
The “Full-flow” output is turned off.
The “Medium-flow comparator inhibitor timer”
starts.
11
The “Supplementary flow open timer” completes
the set time.
The “Dribble-flow“ signal is turned off.
The “Nozzle down“ signal is turned off.
The “Supplementary flow close timer” starts.
7
Net weight reaches the weight of “Final”
–“Preliminary” or more.
The “Medium-flow” signal is turned off.
The “Dribble-flow comparator inhibitor timer”
starts.
8
Net weight reaches the weight of “Final” –“Free
fall” or more.
The “Dribble-flow” signal is turned off.
The “Judgment wait timer” starts.
12
The “Supplementary flow close timer” completes
the set time.
Judgement is made.
If “Under limit”;
Repeat the weighing process from sequence # 9.
If “Acceptable weight” or “Over limit”;
The “An acceptable weight” or “Over limit” is
turned on.
The batch monitoring timer is reset.
The net weight is accumulated automatically.
The data is output from the interface set for auto
print.
13
The container has been filled with ingredient.
The container is removed from the platform
9
The “Judgment wait timer” completes the set time.
Display becomes stable. (Already "Stable" in the
chart on next page.)
If automatic free fall compensation is being used,
its calculation will be made.
Judgement is made.
14
To tare, input Tare signal or press [TARE].
If Sq F-26=”1”(Tared automatically at batch start), tare
is cleared automatically within zero band.