6-7 CALF-14=“4” Weighing Mode
(Loss-In-weigh in built-in automatic program mode)
Out
p
ut si
g
nal Out
p
ut condition
Zero band
Gross weight
≤
Zero band
Full Full
≤
Gross weight
Full-flow Final -
Optional preliminary
≤
Net weight
Medium-flow Final - Preliminary
≤
Net weight
Dribble-flow Final - Free fall
≤
Net weight
Over limit Final + Over limit <
Net weight
Under limit
Net weight
< Final - Under limit
• When an output condition is established, full flow, medium flow, and dribble flow outputs are turned off, but the other
outputs are turned on.
• Once the full flow, medium flow, and dribble flow are turned off, they are not turned on until the next start of batching.
• Over limit / Under limit is activated based on the net weight upon batch finish. (May be changed to customer
programmed control mode operation)
• The zero band is a customer programmed control mode operation.
Weighing process
Sequence # Process
1
• The “Zero band” is output.
• Ingredient continues to be supplied until the “Full” signal is output.
2
• The “Tare” signal is input at stable display.
3
• The “Batch start” signal is input.
• The “Batch start wait timer” starts.
4
• The “Batch start wait timer” completes the set time.
• “Full-flow”, “Medium-flow” and “Dribble-flow” output signals are turned on.
• The “Full-flow comparator inhibitor timer” and “Batch monitoring timer” start.
5
• Net weight reaches the weight of “Final” –“Optional preliminary”.
• The “Full-flow” output is turned off.
• The “Medium-flow comparator inhibitor timer” starts.
6
• Net weight reaches the weight of “Final” –“Preliminary” or more.
• The “Medium-flow” signal is turned off.
• The “Dribble-flow comparator inhibitor timer” starts.
7
• Net weight reaches the weight of “Final” –“Free fall” or more.
• The “Dribble-flow” signal is turned off.
• The “Judgment wait timer” starts.
8
• The “Judgment wait timer” completes the set time.
• Display becomes stable.
• If automatic free fall compensation is being used, its calculation will be made.
• The “Batch Finish” output signal is turned on
• If there is excess or shortage, a judgment result output signal (Over limit or
Under limit) will be turned on. (“Within limit” is on in the chart on next page.)
• The “Batch monitoring timer” is reset.
• The net weight is accumulated automatically.
• The data is output from the interface set for auto print.