Instruction manual

3-4
3-5 Editing Accumulation data
Set point editing modes
There are 8 modes for editing set point data.
Mode # Mode name Description
[0] Mode 0 Retrieves the code number with no set point data setting.
[1] Mode 1
Writes set point data over the set point designated by a code
number.
[2] Mode 2
Clears the set point and accumulation data designated by a code
number.
[3] Mode 3 Clears the accumulation data designated by a code number.
[4] Mode 4 Displays all the set points that have been set.
[5] Mode 5
Writes a tare weight over the preset tare weight designated by a
code number.
[7] Mode 7 Clear all the set point data settings.
[8] Mode 8 Clear all the accumulation data.
Mode [6] and [9] are not in use.
General procedures
1. Enter the set point editing mode.
Press [CODE] [FUNC.] in this order. It shows;
Main display:
“CodE”
Sub display:
“oPErAtE”
Right LEDs: All the LEDs is on while in the mode.
* Press [ESC] to return to the normal mode.
2. Select the mode required.
Select a mode # from the above list with numerical keys.
* Press [ESC] to return to the normal mode.
3. Follow the procedures of each mode.
Follow the procedures on the next page. See the following {Procedures for each mode}.
4. Escape from the set point editing mode.
Press [ESC] to return to the normal mode.