Instruction manual

C-15
Function #
Function name Range
Default
CALF-14 Weighing mode 3
1 Normal batching (Customer Programmed Control Mode)
2 Loss-in-weight (Customer Programmed control Mode)
3 Normal batching (Built-in automatic program mode)
4 Loss-in-weigh (Built-in automatic program mode)
5 Nozzle Controlled Weighing Mode (Built-in automatic program mode)
6 Check weighing 1
7 Check weighing 2
8 Check weighing 3
9 Check weighing 4
See {6. Weighing}
in det
ail.
CALF-15 Preset tare 1
0 Disable
1 Not disabled
When disabled, preset tare can not be set nor recalled.
CALF-16 Distinguish between preset tare and tare 0
0 None (same)
1 Distinguished
When “1” is set (distinguished), "" illuminates on the
lower status display
section when “preset tare” is used and header of serial output becomes "PT"
(preset tare) and "T " (tare)
* Pressing [PRESET TARE] always shows preset value regardles
s of this
setting.
CALF-17
Serial interface; Print preset tare value with net
weight (Si F-01=3, rsF-01=3)
0
0 Not printed
1 Print
CALF-18
Push-zero and tare-clear function when powered on
and when the display is turned on.
0
0 Both push-zero and tare-clear are disabled.
1 Only push-zero is available.
2 Only tare-clear is available.
3 Both push-zero and tare-clear are available.
Push-zero is performed at stable reading. If
unst
able for 10 seconds or longer,
Err
St” (Error message) appears on the
display.
When reading is out of the range of
push-zero,
“Err PZr” is displayed on
the display.
(Press [ESC] to return to the normal mode.)