Specifications
Altivar
®
31 Adjustable Speed AC Drives
Selection
© 2004–2005 Schneider Electric All Rights Reserved
10
4/2005
SELECTION
1)
For a drive equipped with a control potentiometer and with run and stop buttons, add an “A” at the end of the catalog number (for
example, ATV31HO37N4A). This option is not available for 575 V controllers.
2)
These power ratings and currents are for a maximum ambient temperature of 50 °C (122 °F) and a switching frequency of 4 kHz
in continuous operation. The switching frequency is adjustable from 2 to 16 kHz. Above 4 kHz, the drive controller reduces the
switching frequency in the event of excessive temperature rise. The temperature rise is controlled by a PTC probe in the power
module. Derate the nominal current if continuous operation above 4 kHz is required. Derating curves are shown on page 30 as a
function of switching frequency, ambient temperature, and mounting conditions.
3)
Current on a line supply with the indicated short-circuit current rating.
4)
Peak current on power-up, for the maximum voltage (240 V +10%).
5)
For 60 seconds.
6)
4.8 A at 200 V, 4.6 A at 208 V, 4.2 A at 240 V.
7
Refer to “Recommended fuses or Powerpact
®
circuit breakers” on page 26.
208 V -15% / 240 V +10% at 50/60 Hz, single-phase input, three-phase output
ATV31 drive Motor Line supply (input) Drive controller (output)
Catalog
number
1
Power
indicated
on
nameplate
2
Max. line
current
3
Short-
circuit
current
rating
7
Max.
inrush
current
4
Nominal
rated
output
current In
2
Transient
output
current
2,5
Total
dissipated
power at
rated load
at
208 V
at
240 V
kWhpAAkA A A A W
ATV31H018M2 0.18 0.25 3.0 2.5 1 10 1.5 2.3 24
ATV31H037M2 0.37 0.5 5.3 4.4 1 10 3.3 5.0 41
ATV31H055M2 0.55 0.75 6.8 5.8 1 10 3.7 5.6 46
ATV31H075M2 0.75 1 8.9 7.5 1 10 4.8, 4.6, 4.2
6
7.2 60
ATV31HU11M2 1.1 1.5 12.1 10.2 1 19 6.9 10.4 74
ATV31HU15M2 1.5 2 15.8 13.3 1 19 8.0 12.0 90
ATV31HU22M2 2.2 3 21.9 18.4 1 19 11.0 16.5 123
208 V -15% / 240 V +10% at 50/60 Hz, three-phase input, three-phase output
ATV31 drive Motor Line supply (input) Drive controller (output)
Catalog
number
1
Power
indicated
on
nameplate
2
Max. line
current
3
Short-
circuit
current
rating
7
Max.
inrush
current
4
Nominal
rated
output
current In
2
Transient
output
current
2,5
Total
dissipated
power at
rated load
at
208 V
at
240 V
kWhpAAkA A A A W
ATV31H018M3X 0.18 0.25 2.1 1.9 5 10 1.5 2.3 23
ATV31H037M3X 0.37 0.5 3.8 3.3 5 10 3.3 5.0 38
ATV31H055M3X 0.55 0.75 4.9 4.2 5 10 3.7 5.6 43
ATV31H075M3X 0.75 1 6.4 5.6 5 10 4.8 7.2 55
ATV31HU11M3X 1.1 1.5 8.5 7.4 5 10 6.9 10.4 71
ATV31HU15M3X 1.5 2 11.1 9.6 5 10 8.0 12.0 86
ATV31HU22M3X 2.2 3 14.9 13.0 5 10 11.0 16.5 114
ATV31HU30M3X 3 3 19.1 16.6 5 19 13.7 20.6 146
ATV31HU40M3X 4 5 24.2 21.1 5 19 17.5 26.3 180
ATV31HU55M3X 5.5 7.5 36.8 32.0 22 23 27.5 41.3 292
ATV31HU75M3X 7.5 10 46.8 40.9 22 23 33.0 49.5 388
ATV31HD11M3X 11 15 63.5 55.6 22 93 54.0 81.0 477
ATV31HD15M3X 15 20 82.1 71.9 22 93 66.0 99.0 628
ATV31H037M2
531248-10-M.tif
ATV31HU40MX3
531249-15-M.tif
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com