Page 48 MultiWeigher 3000 Operations Manual
The first half on the left hand side of the AQS screen shows the 3 rules that need to be
fulfilled to comply with the AQS.
The other half on the right hand side of the screen shows the 2 rules that need to be fulfilled
to comply with the UTML.
¾ AQS
Weighted Average Compliancy
Target Weight The Target Weight is the weight that needs to be achieved by the
monitored product
This value is editable by the MultiWeigher user
Nominal Weight The Nominal Weight is the weight marked on the end-user / customer
package of the monitored product
This value is editable by the MultiWeigher user from the Set Nominal
Weight field
Weighted Average The Weighted Average is the result of the Sample Average
added to the multiplication result of the Sample SD with the
Sample Correlation Factor
Min Weighted Ave Min Weighted Ave is minimum weighted average being
recorded
Total Counts Total Counts is total number of products being weighed or produced in
a certain production run
Passed Counts Passed Counts is the number of products that weigh the same as the
Nominal Weight
Max Weight Max Weight is the maximum weight of the sample products
Min Weight Min Weight is the minimum weight of the sample products
T1 Error Compliancy
T1 Value T1 Value is the Tolerable Deficiency allowed to meet the AQS
standard
T1 Counts T1 Counts is the number or shortfall of products allowed to meet the
requirement of the T1 Error rule
T1 Rejects T1 Rejects is the number of rejects needed to comply with the T1 Error
rule
T2 Error Compliancy
T2 Value T2 Value is a value double the T1 value