Product specifications
Page 58
8.11.
8.11.8.11.
8.11. Output for Foreign Matter Detection
Output for Foreign Matter DetectionOutput for Foreign Matter Detection
Output for Foreign Matter Detection
Procedure:
1 When the sensor detects foreign matter and sends the signal to the AD-4404, the
foreign matter detection is output until the AD-4404 judges the signal and totals it.
The output can be used to control peripherals.
This signal means that there is foreign matter between the sensor and the weighing
conveyor.
Procedure for a stop input during the detection:
1 When a stop input is entered during the detection, the status changes to pause.
2 All timers are held. Status indicators blink.
Refer to " 6.3. Foreign Matter Detection".
8.12.
8.12.8.12.
8.12. Evaluation Output
Evaluation OutputEvaluation Output
Evaluation Output
There are three types of output for judgement.
Comparison output.
Output to selectors.
Buzzer output.
8.12.1.
8.12.1.8.12.1.
8.12.1. Comparison
ComparisonComparison
Comparison Output
Output Output
Output
The comparison output is used to input signals to a PLC and to a peripheral indicator.
It is output, when averaging weight and judging it.
Kind of output: LoLo, Lo, OK, Hi, HiHi, Foreign matter, Duplication, Crush, NG.
Relations: Conveyor stop condition [5q f-21], Sub-display, I/O output,