Product specifications

Page 55
8.5.3.
8.5.3.8.5.3.
8.5.3. Detecting Gross Value above Zero Band
Detecting Gross Value above Zero BandDetecting Gross Value above Zero Band
Detecting Gross Value above Zero Band
Select Over zero band of gross of the Detector [5q f-29] [3].
Procedure:
1 The article is moved on the weighing conveyor.
2 When the gross is above the zero band, the detection has effect.
Caution
This method can not be used for high velocity and intolerable vibration of the
weighing conveyor, because it can not detect duplication of the articles or the
position of the article.
8.5.4.
8.5.4.8.5.4.
8.5.4. Detecting Gross Value within Zero Band
Detecting Gross Value within Zero BandDetecting Gross Value within Zero Band
Detecting Gross Value within Zero Band
Select Zero band of gross of the Detector [5q f-29] [4].
Procedure:
1 When the gross value is within the zero band, the detection has effect.
8.6.
8.6.8.6.
8.6. Check to Forward the Article
Check to Forward the ArticleCheck to Forward the Article
Check to Forward the Article
The function is used to forward the compared article from the weighing conveyor.
Select OK mode of the Weighing mode [5q f-1] [3] to use the check.
Select the mode at Detector [5q f-29].
Procedure for this mode:
1 When the comparison has effect,
the article is forwarded from the weighing conveyor and
Conveyor stop delay timer [5q f-59] starts.
2 The conveyor moves, until
Conveyor stop delay timer [5q f-59] is up.