Product specifications
Page 51
8.1.2.
8.1.2.8.1.2.
8.1.2. Dynamic
Dynamic Dynamic
Dynamic Zero Tracking Function
Zero Tracking FunctionZero Tracking Function
Zero Tracking Function
The function is used during automatic mode and conveyor stop mode, also when the
conveyor is moving.
The function can be used for gross display.
To average the weighing value is performed at a constant time before loading the
article.
The function reduces one digit of an error in each zero tacking time, when the
compensation value is more than ±1.0 digit. The function does not zero the display
value all at once.
Concerning Parameters
[5q f-71]
Zero tracking back timer
0.1s interval [0-50]
[5q f-72]
Zero tracking average timer
0.1s interval [0-50]
[5q f-73]
Zero tracking MIN interval
0.1d interval [0-999]
[5q f-74]
Zero tracking amplitude
0.1d interval [0-999]
[Function] - [Set function] - [Sequence] - [Zero track]
Position senso
r
Eval dela
y
time
r
5q f-42
Judgement
Chatterin
g
time
r
Gross
Detection
5q
f
-
72
, Zero tracking average time
r
It is time to perform zero tacking.
5q
f
-
7
1, Zero tracking back time
r
It is time to stop zero tacking before
weighing the article.
Judgement
Zero tracking average timer
Z
ero tracking MIN interval
5q
f
-
73
, Zero tracking MIN interval
If the article is detected within time
of 5q f-73, zero tracking is not
attained.
Detection
Zero tracking is calculated at this time
0
5q
f
-
72
,
Zero tracking average timer
5q
f
-
7
4,
Zero tracking amplitude
5q f-43
5q f-72
5q
f
-
73