Product specifications

Page 37
6.6.
6.6.6.6.
6.6. Simple Mode
Simple ModeSimple Mode
Simple Mode
The simple mode is used to compare the weighing value and the setpoints.
Setpoints, means preset value to be used comparison, are used for buzzer,
comparison display and output. There are five setpoints of LoLo, Lo, OK, Hi, HiHi.
The current weighing value and the comparison display are always updated. The
comparison display, the comparison output and buzzer are turned off, when the
weighing value is within the zero band.
Accumulation, is achieved at judgement, ignores stop mode and operation mode, and
is not achieved at pause.
Concerning Principal Items
(Including Parameter Example)
Address
Parameter
Address name
Parameter name
Description
5q f-01
5
Weighing mode
Simple mode
5q f-02
1
Selection of comparison
3 levels with target
Setpoints and comparison method
Target, Lo (light), Hi(heavy)
5q f- 5
11011111
Buzzer condition 1
Buzzer sounds without OK.
1: buzzer sounds, 0: no buzzer
AD
-
4404
Current weight can be checked
with light and buzzer.
Loadcell
OK