Product specifications
Page 34
Drawing: OK Mode
If weight is OK, conveyor moves.
Pack them and press
the START key.
Weighing conveyo
r
Loadcell
Forwarding conveyo
r
Position senso
r
If weight is Lo or Hi,
conveyor does not move.
The passed article is detected.
OPERATE, Output
Buzzer , Output
Hi, Output
Lo, Output
Average timer
Setpoint, Input
Position sensor
Eval delay timer
OK, Output
5q f-42
Judgement
Chattering timer
Hi
OK
Conveyor, Output
Buzzer ON timer
5q f-43
5q
f
-44
5q f-41
Zero band, Output
0
Target
Lo (Lower limit)
Hi (Upper limit)
Net
0
Zero band
Gross
Stop operation, Input
Start operation, Input
Main display
Comparison display
Conveyor stop delay timer
Jud
g
ement
OK
Tail detection
Tail detection
5q f-59
Jud
g
ement