6.2.
6.2.6.2.
6.2. Conveyor Stop Mode
Conveyor Stop ModeConveyor Stop Mode
Conveyor Stop Mode
The conveyor stop mode is the function that the article is stopped on the weighing
conveyor for accurate measurement.
When the gross value is within zero band, the weighing value is not judged.
The mode can be used with foreign matter detection.
Caution
Set parameter of Tail Edge
Tail EdgeTail Edge
Tail Edge to place the article on the weighing conveyor
correctly.
[5q f-29] [2] [Function] - [Set Function] - [Sequence] -[Control] - [Tail Edge]
Concerning Principal Items
(Including Parameter Example)
Address
Parameter
Address name
Parameter name
Description
5q f- 1
2
Weighing mode
Conveyor stop mode
5q f- 2
1
Selection of comparison
3 levels with target
Setpoints and comparison method
Target, Lo (light), Hi(heavy)
5q f-29
2
Detector
Tail edge
Detection method
Position sensor detects the end of an article.
5q f- 5
11011111
Buzzer condition 1
Buzzer sounds without OK.
1: buzzer sounds, 0: no buzzer
5q f-21
00000110
Conveyor stop condition Conveyor stops for foreign matter or crush.
5q f-22
11011111
Selector 1 condition Article is separated by selector 1 without OK.
5q f-42
Chattering timer
The time to ignore the position sensor.
Range is 0.00 to 99.99 sec.
5q f-43
Eval delay timer
The time between detecting an article and
averaging it. Range is 0.00 to 99.99 sec.
5q f-44
Average timer
Time to average the weighing value.
Range is 0.00 to 99.99 sec.
5q f-45
0.00
Compare Output timer
Output pulse is turned on until next article
detection. Range is 0.00 to 99.99 sec.
5q f-46
Selection out 1 delay timer
Delay time of selector 6 after judgement.
Range is 0.00 to 99.99 sec.
5q f-52
Select output 1 timer
The output time of selector 1.
Range is 0.00 to 99.99 sec.
Selector only passes OK
The end of the
article is detected
Weighing conveyo
Loadcell
Leading conveyo
r
Forwarding conveyo
r
Selector 1
Position senso
r
To light
OK
The article is stopped and
weight is judged.