Page 142 AD-4404
Category address
:
[Function] - [Set Function] - [Control I/O] - [Output]
The list to assign the function for the output terminal of the control I/O
No. Function Description No. Function Description
0 No function 23 Alam 1
1 Stable 24 Alam 2
2 Zero band 25 Zero error
3 Full 26 Capacity exceeded (Out of range)
4 LoLo 27 Buzzer
5 Lo 28 Tare
6 OK 29 Center of zero
7 Hi 30 Gross display
8 HiHi 31 Net display
9 Foreing matter detection 32 During hold
10 Duplication 33
11 NG 34
12 Finish target 35
13 During opetation 36
14 Conveyor 37
15 Busy 38
16 Managing foreign matter 39
17 Crush 40
Internal reservation
18 Internal reservation 41 Selection output 1
42 Selection output 2
19
Online. If weighing sequence is
available, 1Hz pluse is output.
43 Selection output 3
20 Internal reservation 44 Selection output 4
45 Selection output 5
21
Input acknowledge. If there is an input
signal, 0.5 sec. pulse is output.
46 Selection output 6
22 Weighing sequence error
Default functions of the output terminals of the control I/O.
Category address symbol Terminal name Description of default settings Default No.
0utf- 1
Output terminal B1 Lo 5
0utf- 2
Output terminal B2 OK 6
0utf- 3
Output terminal B3 Hi 7
0utf- 4
Output terminal B4 NG 11
0utf- 5
Output terminal B5 Conveyor 14
0utf- 6
Output terminal B6 Selection output 1 41
0utf- 7
Output terminal B7 Buzzer 27
0utf- 8
Output terminal B8 Finish of target count 12
0utf- 9
Output terminal B9 Weighing sequence error 22
0utf-10
Output terminal B10 Alam 1 23
0utf-11
Output terminal B11 Alam 2 24