Product specifications
AD-4404 Page 139
Category address
:
[Function] - [Set Function] - [Sequence] - [Zero track]
Parameters for Dynamic Zero Tracking Function
Category
address
symbol
Name Descriptions
Range
and
choices
Default
5q f-71
Zero tracking
back timer
The time to stop zero tacking before
weighing the article.
0.0 to
5.0 s
1.0 s
5q f-72
Tracking
average timer
Average time.
0.0 to
5.0 s
1.0 s
5q f-73
Tracking MIN
interval
Minimum interval between weighings.
If next weighing performs before the
timer is up, zero tracking is not
performed.
0.0 to
99.9 s
10.0 s
5q f-74
Tracking
amplitude
Tolerance value to perform zero tacking.
If absolute average value of zero
tracking is above this parameter, zero
tracking is not performed.
0.0 to
99.9 d
0.0 d
Refer to "8.1.2. Dynamic Zero Tracking Function".
s : second, d: digit
Position senso
r
Eval dela
y
time
r
5q f-42
Judgement
Chatterin
g
time
r
Gross
Detection
5q
f
-
72
, Zero tracking average time
r
It is time to perform zero tacking.
5q
f
-
7
1, Zero tacking back time
r
It is time to stop zero tacking before
weighing the article.
Judgement
Zero tracking average timer
Zero tracking MIN interval
5q
f
-
73
, Zero tracking MIN interval
If the article is detects within time of
5q f-73, zero tracking is not
attained.
Detection
Zero tracking is calculated at this time
0
5q
f
-
72
,
Zero tracking average timer
5q
f
-
7
4,
Zero tracking amplitude
5q f-43
5q f-72
5q
f
-
73