Product specifications
Page 118 AD-4404
10.3.
10.3.10.3.
10.3. Test Mode
Test ModeTest Mode
Test Mode
The test mode is used to check the indicator and weighing system with a test signal.
When the test mode is used, the weighing sequence is stopped.
Caution
Turn off the peripherals before test. The test mode outputs a test signal.
Therefore, the devices connected to system are influenced and it may cause
mis-operation.
10.3.1.
10.3.1.10.3.1.
10.3.1. Testing Control I/O Function
Testing Control I/O FunctionTesting Control I/O Function
Testing Control I/O Function
Terminal displays the current input data.
One of terminal B turns on every one second and in order. The active terminal
displays "1".
10.3.2.
10.3.2.10.3.2.
10.3.2. Testing Built
Testing BuiltTesting Built
Testing Built-
--
-in RS
in RSin RS
in RS-
--
-485 Interface
485 Interface485 Interface
485 Interface
Each time to press the ENTER key, the test data "ST,GS,+0000000kg CR LF" is
output.
The received data is displayed, when data is output.
: CR
: LF
10.3.3.
10.3.3.10.3.3.
10.3.3. Testing Built
Testing BuiltTesting Built
Testing Built-
--
-in Current Loop Output
in Current Loop Outputin Current Loop Output
in Current Loop Output
Each time to press the ENTER key, the test data "ST,GS,+0000000kg CR LF" is
output.
The received data is displayed, when data is output.
: CR
: LF
123 kg
CONTROL 00010001000
a11 a1
I/O 00100000000
b11 b1
Input terminal A1
Output terminal B1
Sent data
123kg
ST,GS,+0000000kg
Cloop 5nd
Sent data
123kg
RNET
ST,GS,+0000000kg
r5-485 rcu and 5nd
Received data