Product specifications

Page 10
2.2.2.
2.2.2.2.2.2.
2.2.2. Symbols
SymbolsSymbols
Symbols
Main display
While weighing sequence mode stops, weighing data is displayed.
While weighing sequence mode operates, each judged weighing
value is held and is displayed.
Sub display
Code numbers, operation guidance, graph, setpoint and others are
displayed selectively.
Weighing unit
The indicator that is displayed when the weighing unit is selected in
the calibration mode.
Status indicator The current weighing status is displayed.
Graphic status
indicator
The current weighing situation is displayed with symbols.
The classification number is displayed, when an error occurred or
an alarm is indicated.
STABLE The sign is illuminated when the current weighing display is stable.
GROSS The sign is illuminated when the main display is the gross data.
NET The sign is illuminated when the main display is the net data.
TARE ENT
Tare entered.
The sign is illuminated when a tare value stored.
HOLD The sign is illuminated when the main display is held.
CZ
Center of zero.
The sign is illuminated when the gross value is within the center of
the zero point of zero calibration.
ZR.ERR
Zero error.
Error message for zeroing the gross data of the main display.
SQ.ERR
The sequence error sign.
Indicates a weighing sequence error.
ALARM 1 An error sign preset to alarm 1.
ALARM 2 An error sign preset to alarm 2.
Operate
The sign is illuminated while the weighing sequence works.
The sign is turned on and off while the weighing sequence is pause.
BUSY
The sign is illuminated while material is weighed and data is processed.
ZTR
Zero track function. The sign is illuminated for one second when
zero track function works.
0. BAND
The zero band sign.
When the gross data is within the range of the zero band (around
the zero point), this sign is illuminated.
D.COMP
Dynamic compensation function to correct weighing value. The sign is
illuminated when the coefficient is not 1 in the automatic mode.