Manual

HV-WP/HW-WP Series Page 51
16. RS-232C Serial Interface
16.2. Stream Mode
The scale outputs the current display data at the time when refreshing the display.
The scale does not output data while in the setting mode.
Averaging of function table Refresh rate
A
f13 0 Fast response
Sensitive value
Approximately 7 times/s while the display is unstable,
Approximately 4 times/s when the display is stable
A
f13 1 Ú
A
f13 2 Slow response
Stable value
Approximately 4 times/s
A
16.2.1. Preparation and Performance (Examples)
Step 1 Turn off the display.
Press the ON/OFF switch while the ZERO switch is
pressed and held. The function table is displayed.
Step 2 Press the ENTER switch to display f4 ("Baud
rate"). Select a parameter of "Baud rate" with the
switch.
Step 3 Press the ENTER switch to display f5 ("Output
mode").
Select "Stream mode ( f5 0 )" with the
switch.
Step 4 Press the ENTER switch to display f15 ("Format").
Select "Format 1 ( f15 0 )" with the switch.
Step 5 Press the ENTER switch to display end .
Step 6 Press the ENTER switch to store the new
parameters. The scale returns to the normal
weighing mode and outputs the data continuously.
P ress
and
hold
Press
S
T
, 0 0 0 0 . 0 0 0
k g
U S , 0 0 1 0 . 6 4 5
k g
S
T
, 0 0 1 0 . 6 4 4
k g
F u n c t i o n
t a b l e
D i splay
off
B a u d
r a t e
S t r e a m
m o d e
F o r m a t
1
W e i ghing
value