Manual
HV-WP/HW-WP Series Page 47
15. The Function Table
Item Display Meaning and purpose
A
f9
Not used
The details of the full/dribble batch function (f6 9) A
f10 0 #
Reaching final value and pressing the F switch, the current
process is finished.
A
A
f10 1
Reaching final value and displaying the stability mark, the current
process is finished automatically.
A
A
f10 2
Pressing the SET switch, the scale automatically tares and starts
the full/dribble batch process. Reaching final value and pressing
the F switch, the current process is finished.
A
A
A
Full/Dribble
batch
sub-func-ti
on
f10 3
Pressing the SET switch, the scale automatically tares and starts
the full/dribble batch process. Reaching final value and
displaying the stability mark, the current process is finished.
A
A
A
Address for RS-422 / RS-485 for option OP-04 A
f11 00#
Address
f11 01
~
f11 99
Use This address can be set from 01 to 99. It is possible for a
computer to control the scale assigned an address.
(RS-232C should be set to "00".)
A
A
A
The function to hold the current display value. When the value
becomes nearly-zero or the weighing value changes more than
25% +30 digits, hold display is canceled.
A
A
A
f12 0 # Not used A
f12 1
The hold function is ON or OFF alternately by the F switch.
A
Hold
f12 2
Displaying the stability mark, the display is held. A
Selects readability and response. A
f13 0 # Fast response, sensitive value A
f13 1
Ú
A
Averaging
f13 2
Slow response, stable value A
Selects a storable minimum unit mass in the counting mode. A
f14 0 # Stores a unit mass in the unit of a digit. A
f14 1
Stores a unit mass in the unit of one eighth digit. A
Precision
of unit
mass
f14 2
Stores a unit mass, if the total of the sample mass is greater than
5 digits.
A
A
Refer to "16.1. Data Format". A
f15 0 # Format 1. (A&D general format for scales, balances) A
f15 1
Format 2. (Older HV-A/ HW-A format) A
f15 2
Not used
Format
f15 3
Format 1 (Return command is available for all commands.)
f16
Not used. A
f17
The function number “f17” is not displayed.
When displaying
000000
,
press the ENTER switch to cancel.
The "#" is factory settings
The "nearly-zero" is within ±5 digits from zero point in the unit of kg.
The "digit", a unit of display, is equivalent to the minimum measurable mass.