7. Basic Operation
7. Basic Operation
7.3. Weighing Range for the HV-WP Series
This is the function to select a weighing range for the HV-WP series.
The mass value is displayed within a selected range.
Select automatic range (f2 0) or manual range (f2 1) in the function table.
Operation and Performance
Function table Meaning and purpose
A
f2 0
Automatic range
The weighing range changes automatically, if the weighing
value proceeds from narrow range to wide range when
placing articles on the weighing pan.
When there is nothing on the weighing pan and the zero point
mark is displayed, it changes to the minimum range
automatically.
Press the ZERO switch to change to the minimum range,
when there is nothing on the weighing pan and the zero point
mark is not displayed due to net display or zero error.
A
A
A
A
A
A
A
A
A
f2 1
Manual range
Press the RANGE switch to expand the range.
Press the RANGE switch to change to the minimum range,
when there is nothing on the weighing pan and the zero point
mark is displayed.
Press the ZERO switch and the RANGE switch to change to
the minimum range, when there is nothing on the weighing
pan and the zero point mark is not displayed due to net display
or zero error.
A
A
A
A
A
A
A
A
A
Weighing Range
Models Weighing Range
A
HV-15KV-WP 3kg, 6kg, 15kg
A
HV-60KV-WP 15kg, 30kg, 60kg
A
HV-200KV-WP 60kg, 150kg, 220kg