User Guide Part 2

17 7signal solution 70
7signal Solutions, Inc., 526 S. Main Street, Akron, Ohio 44311, USA, 855-763-9526, info@7signal.com, www.7signal.com
7signal Sapphire Carat User Guide Release 5.0
Table 10: Test execution order on access point centric test profile, remain associated
Attach AP1
Attach AP2
Ping AP1
TCP download AP1
TCP upload AP1
Ping AP2
Detach AP1
Attach AP3
TCP download AP2
TCP upload AP2
Ping AP3
TCP Download AP3
Detach AP2
Attach AP1
TCP upload AP3
Managed scan
Ping AP1
MOS uplink AP1
Detach AP3
Attach AP2
MOS downlink AP1
Ping AP2
MOS uplink AP2
MOS downlink AP2
Detach AP1
Detach AP2
Attach AP3
Ping AP3
MOS uplink AP3
MOS downlink AP3
Noise monitor
Detach AP3
17.5 Operations on templates
Templates are for copying and editing. There are two different supported methods for that,
“Duplicate” to make a fresh copy of the sample profile and “Copy as essid” that adds the
template profile to an existing test profile.
17.5.1 Duplicate
1. Select “Manage | Test Profiles” to open the management tree on the left.
2. Choose the appropriate template and right-click for the submenu.
3. Select “Duplicate” to open the Test Profile pane.
4. Give a name to the new Test Profile.
5. Bound Tests window is for informative purposes here only. Editing if desired is
available later.
6. Select “Execution mode”. Access point centric execution mode also allows the
monitoring station to remain associated between (active) tests.
7. In “Common Values” one may enter test parameters that apply to every test in the
profile.
8. Saving options
a. Select “Cancel Changes” to undo changes.
b. Select “Keep Changes to save the intermediate work.
c. Select “Save All Changes” to finalize the work on this pane.