User Guide
4 Installing 7signal Sapphire 15
7signal Solutions Inc., 526 S. Main Street, Akron, Ohio 44311, USA, 855-763-9526, info@7signal.com,
www.7signal.com
7signal Sapphire Deployment Guide Release 5.0
4.5.2 Standard Eye Ceiling Installation
On top of Eye unit there are three slots for screws. Insert screws (Pan Head Stainless Screw,
DIN 7985 M5x12) on top of the Eye unit. The head of the screw is supposed to have few
millimeters of space between the inserts on the unit top.
Afix the ceiling mounting plate to the ceiling (pictured right below).
Mount the Eye unit on the ceiling mounting plate by inserting the screw tops into the plate holes.
Make sure that the marking ‘CABLE’ is pointed towards connectors. Turn the unit and feel it
snatching into the plate.
4.5.3 Wall Mount Installation (optional)
On top of Eye unit there are three slots for screws. Insert screw thread taps (Socket Set Screw
Cone Point, DIN 914, M5x20) on top of the Eye unit. In wall-mounting the screw does not have
any head.