User Guide

4 Installing 7signal Sapphire 13
7signal Solutions Inc., 526 S. Main Street, Akron, Ohio 44311, USA, 855-763-9526, info@7signal.com,
www.7signal.com
7signal Sapphire Deployment Guide Release 5.0
Restart Eye software:
# 7config run restart
Same problem can occur also on Ethernet interface. In that case, set the interface name
back to “eth0
4.4 Setting up Micro Eyes
4.4.1 Set IP configuration
Login to Micro Eye as root by using SSH client. Default IP address is 192.168.0.1 and password
is “7signal”:
# ssh root@192.168.0.1
Use system-config-network-tui tool to configure desired IP address, network mask and default gateway:
# system-config-network-tui
Save the configuration and reboot Micro Eye:
# reboot
4.5 Mounting Eyes
Mount Sapphire Eye in the most centralized location of the WLAN area. Eye can be installed on
the ceiling, wall or mast.
Sapphire Eye has extremely sensitive radio technology inside
The receiving signal is 10-20dB stronger than the basic WLAN end-user
The transmitted signal is 5-6dB stronger at the access point side than with the basic
WLAN end-user
For best accuracy of the WLAN performance, the Sapphire Eye location should be selected so that: