User's Guide

20 Active Tests 65
7signal Ltd, Panuntie 6, FI-00620 HELSINKI, FINLAND, +358 40 777 7611, info@7signal.com, www.7signal.com
7signal Sapphire Carat Carat User Guide Release 3.0
The results are displayed in two tables as seen below. The tables are active and the column
names support sort-orders.
The table “Client Scan Results” shows individual clients and their antenna sectors. By activating
a row on this table, more detailed information on the client is displayed on the table named
“Client Results” below.
20.8 “MOS test”
This test creates a VoIP call between Sapphire Eye and Sonar. Both uplink and downlink call
quality are measured, simultaneously and independently.
1. In the Network topology, select the Eye that will run the test
2. Right-click and select ”Manual tests | Http test”
3. Define the test target in the target area:
a. Select the Sonar against which you want to run the test
b. Select an access point from the pull-down menu
c. Select the Eye’s IP address (DHCP or static)
i. If static, enter the (1) local IP address, (2) local netmask, and (3)
gateway
4. Configure the test data (see separate instructions)
5. Select “Execute”
20.9 MOS test parameters
1. Select the initial display format for the results (Table/Graph)
2. Select the direction of the test (Downlink/Uplink)
3. Select the codec to be used in the test (VoIP Codec):