User's Manual

70
Upload tests
This test gives an indication of an access point’s FTP or uplink uplink capacity.
1. In the Network topology, select the Eye that will run the test
2. Right-click and select ”Manual tests”
3. From the submenu select either “FTP Upload Test or “UDP Upload Test
4. Configure the test target in the target area:
a. Select the Sonar against which you want to run the test, or type another IP
address
b. Select an access point from the pull-down menu
c. Select the Eye’s IP address (DHCP or static)
i. If static, enter the (1) local IP address, (2) local netmask, and (3)
gateway
5. Set up the test options:
a. Select the amount of data from the pull-down menu
b. (UDP only): Packet size to be used (small = 256, medium = 1024, large =
32768 bytes)
c. (UDP only): Sender (Eye) port. Default 0 means that MOS test ports shall be
used. User-given port overrides this setting. Please observe possible firewall
settings.
d. (UDP only): Receiver (Sonar) port. Default 0 means that MOS test ports shall
be used. User-given port overrides this setting. Please observe possible
firewall settings.
e. Specify how many times the test is to be run
f. Select the display format for the results from the pull-down menus