User's Manual

69
Download Tests
This test gives an indication of an access point’s FTP or UDP downlink capacity.
1. In the Network topology, select the Eye that will run the test
2. Right-click and select ”Manual tests”
3. From the submenu select either “FTP Download Test” or “UDP Download Test”
4. Specify whether you want to run the test against a Sonar or another target
5. Select the Sonar against which you want to run the test, or type another IP address
6. Select an access point
7. Select the Eye’s IP address (DHCP or static)
a. If static, enter the (1) local IP address, (2) local netmask, and (3) gateway
8. Set up the test options
a. Select the amount of data transferred at one time
b. (UDP only): Packet size to be used (small = 256, medium = 1024, large =
32768 bytes)
c. (UDP only): Sender (Sonar) port. Default 0 means that MOS test ports shall
be used. User-given port overrides this setting. Please observe possible
firewall settings.
d. (UDP only): Receiver (Eye) port. Default 0 means that MOS test ports shall
be used. User-given port overrides this setting. Please observe possible
firewall settings.
e. Select the display format for the results
f. Select how many times the test is to be run
9. Select “Execute”
10. The results are displayed in a table as shown below
Note: You can change the table type even after the test is executed