O?2/3"$;U:A,"1.;;+G,@.;>"
! The!network!speed!dome!can!be!connected!with!alarm!inputs!(0~5VDC).!
! Refer!to!the!following!diagrams!for!alarm!output:!!
JQC-
3FG
Relay
30VDC
GND OUT
L N
220V AC
Relay Output
Dome
(10 A 250VAC)
Diagram (left)
Diagram(right)
1A
OUT(n)
OUT(n)
+
-
DC
DC Load
Relay Output
Dome
OUT(n)
OUT(n)
!
Figure!1?8 Alarm!Out!Connections!
The!alarm!provides!the!relay!output,!and!the!external!power!supply!is!required!when!it!connects!to!the!alarm!device.!!
! For!DC!power!supply!(left!diagram),!the!input!voltage!must!be!no!more!than!30VDC,!1A.!!
! For!AC!power!supply,!the!external!relay!must!be!used!(right!diagram)!to!prevent!damages!to!the!speed!dome!and!
avoid!risk!of!electric!shock.!
!