Installation Manual | VISIX PTZ Network Camera VISIX PTZ Network Camera VSX-‐PTZ-‐2MP-‐EXT20,VSX-‐PTZ-‐2MP-‐EXT, VX-‐2M-‐OP-‐PTZ20X and VX-‐2M-‐OP-‐PTZ30X Installation Manual 10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.
Installation Manual | VISIX PTZ Network Camera Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual applies to VSX-‐PTZ-‐2MP-‐EXT20,VSX-‐PTZ-‐2MP-‐EXT, VX-‐2M-‐OP-‐PTZ20X and VX-‐2M-‐OP-‐PTZ30X 5-‐Inch Speed dome PTZ network cameras.
Installation Manual | VISIX PTZ Network Camera Regulatory Information FCC Information FCC compliance: This equipment has been tested and found to comply with the limits for a digital device, pursuant to part 15 of the FCC Rules.
Installation Manual | VISIX PTZ Network Camera Safety Instruction These instructions are intended to ensure that the user can use the product correctly to avoid danger or property loss. The precaution measure is divided into ‘Warnings’ and ‘Cautions’: Warnings: Serious injury or death may be caused if any of these warnings are neglected.
Installation Manual | VISIX PTZ Network Camera Cautions: ! Make sure the power supply voltage is correct before using the camera. ! Do not drop the camera or subject it to physical shock. ! Do not touch sensor modules with fingers. If cleaning is necessary, use a clean cloth with a bit of ethanol and wipe it gently.
Installation Manual | VISIX PTZ Network Camera Table of Contents 1 INSTALLATION ......................................................................................................................................................................... 7 1.1 INSTALLATION AND CABLING .....................................................................................................................................................................
Installation Manual | VISIX PTZ Network Camera 1 Installation Please make sure that the device in the package is in good condition and all the assembly parts are included. NOTE: Do not drag the speed dome with its waterproof cables as shown in Figure 1-‐1, otherwise the waterproofing can be damaged and rendered ineffective.
Installation Manual | VISIX PTZ Network Camera Back Box Lock Screw Lens Cover Sticker Protective Foam Lower Dome Figure 1-‐2 Remove the Lower Dome 4) Install the dome mount. Please refer to the related sections in Section 2 and Section 3 for specific installation methods with different mounts.
Installation Manual | VISIX PTZ Network Camera Steps: 1) Apply thread tape to the thread of the pendant adapter and rotate the pendant adapter to the mount. Secure the pendant adapter to the mount with a set screw (supplied).
Installation Manual | VISIX PTZ Network Camera Figure 1-‐5 Align the Direction Label ③ Figure 1-‐6 Mount the Dome 10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.
Installation Manual | VISIX PTZ Network Camera Connecting the Cables Before you start: Please make sure the power of the dome is off before connecting the cables. The cable interfaces of speed dome are shown in the following figures. Please refer to the following figure to connect the cables.
Installation Manual | VISIX PTZ Network Camera Alarm In/Out Connections ! The network speed dome can be connected with alarm inputs (0~5VDC).
Installation Manual | VISIX PTZ Network Camera 2 Mounting Applications Before you start: ! For cement wall, you need to use the expansion screw to fix the mount. The mounting hole of the expansion pipe on the wall should align with the mounting hole on the mount. ! 1.
Installation Manual | VISIX PTZ Network Camera ! The wall must be thick enough to install the expansion screws. ! Please make sure that the wall is strong enough to withstand more than 8 times the weight of the dome and the mount.
Installation Manual | VISIX PTZ Network Camera 4) Install the speed dome on the mount. Please refer to Section 1.2 Installation and Cabling for installation details. Note: Follow the same instructions described above for the short-‐arm wall mounting. For outdoor applications, please adopt the water-‐proof measures.
Installation Manual | VISIX PTZ Network Camera ! Mounting Accessories Figure 2-‐7 Hex Screws (M8×30), Nuts, Spring Washers and Flat Washers Corner Mounting Before you start: The corner mounting is dependent on the indoor/outdoor 90° solid corner construction.
Installation Manual | VISIX PTZ Network Camera Nuts and Washers Figure 2-‐8 Pull the Power Line NOTE: Make sure that the cables have enough length. For outdoor applications, please apply the sealant around the center hole for waterproof. 1) Attach the gasket then the wall mount to the corner adapter.
Installation Manual | VISIX PTZ Network Camera 3) Install dome to the mount. Please refer to Section 1.2 Installation and Cabling for installation details. NOTE: Follow the same instructions described above for the short-‐arm wall mounting. For outdoor applications, please adopt the water-‐proof measures.
Installation Manual | VISIX PTZ Network Camera Figure 2-‐12 Stainless Steel Hoops ! Mounting Accessories Figure 2-‐13 Hex Screws (M8×30) and Spring Washers Pole Mounting Before you start: The pole mounting is dependent on the indoor/outdoor solid pole construction.
Installation Manual | VISIX PTZ Network Camera Figure 2-‐14 Assemble the Pole Adapter Install the pole adapter. 1) Pull the cables through the center hole. 2) Secure the three stainless steel hoops to the pole, and tighten the screws of the hoops with a screwdriver.
Installation Manual | VISIX PTZ Network Camera Figure 2-‐16 Install the Wall Mount 3) Install the speed dome to the mount. Please refer to Section 1.2 Installation and Cabling for installation details. NOTE: Follow the same instructions described above for the short-‐arm wall mounting.
Installation Manual | VISIX PTZ Network Camera Protective Foam Back Box Lower Dome Lens Cover Sticker Figure 2-‐17 Remove the Protective Accessory 4) Drill a hole on the ceiling according to the drill template (supplied). NOTE: ±2mm of the diameter of the circle is tolerable.
Installation Manual | VISIX PTZ Network Camera Lock Lock Figure 2-‐19 Locks and Lock Screws 2) Push the back box into the mounting hole in the ceiling 3) Tighten the lock screws with the screwdriver and the locks will automatically rotate outwards to secure the in-‐ ceiling mount to the ceiling.
Installation Manual | VISIX PTZ Network Camera Figure 2-‐21 Install the Trim Ring 1.6 CEILING MOUNTING APPLICATIONS Before you start: The ceiling mounting is dependent on the indoor/outdoor solid ceilings construction. The following are the mandatory preconditions for ceiling mounting: ! The thickness of the ceiling must ranges from 5mm to 40mm.
Installation Manual | VISIX PTZ Network Camera Figure 2-‐22 Remove the Screws 2) Remove the in-‐ceiling mount. Figure 2-‐23 Remove the Mount 3) Install 4 bolts to the screw holes as shown in Figure 2-‐24. 10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.
Installation Manual | VISIX PTZ Network Camera Figure 2-‐24 Install the bolts Wiring For Ceiling Mounting Applications The cables of dome can be routed either from the top or the side of the back box, as shown in Figure 2-‐25.
Installation Manual | VISIX PTZ Network Camera Cable Hole Screw Holes Figure 2-‐26 Mark the Screw Positions 6) Secure the mounting base to the ceiling with set screws. ! If the speed dome is installed on a wooden wall, use the self-‐tapping screws to secure the mounting base.
Installation Manual | VISIX PTZ Network Camera Push forwards Push upwards Line up Spring Lock clip Figure 2-‐28 Attach the Back Box to the Mounting Base NOTES: ! Please remove the protective film on the lower dome after the installation is finished. ! Do not touch the bubble of the lower dome directly by hand.
Installation Manual | VISIX PTZ Network Camera Appendix Appendix 1 Statics, Interference Lightning and Surge Protection This product adopts TVS plate lightning protection technology to avoid damage caused by pulse signal that is below 3000W, like instantaneous lighting stroke, surging, etc.
Installation Manual | VISIX PTZ Network Camera When the speed dome is installed in environment where is relatively insulating to the earth, e.g., cement pole or cement wall, then only the control center requires proper grounded locally. Refer to the following figure.
Installation Manual | VISIX PTZ Network Camera NOTES: ! Because the signal transmission media of fiber optical speed dome and network speed dome are isolated from the control center, they must be grounded locally to protect dome against damages.
Installation Manual | VISIX PTZ Network Camera Grounding for Metal Pole Installation: When the speed dome is installed in environment where is conductive to the earth, e.g., metal pole, then the grounding of dome can be achieved by the properly grounded metal pole, meanwhile, the control center must be grounded locally as well.
Installation Manual | VISIX PTZ Network Camera Appendix 2 Waterproof NOTES: ! The long-‐arm wall mount is recommended for the outdoor application of speed dome. ! You cannot use the short-‐arm wall mount or pendant mount for outdoor application, because it is not water-‐ proof.
Installation Manual | VISIX PTZ Network Camera Long-‐arm Wall Mount The long-‐arm wall mount is recommended for the outdoor application. The arm of wall mount is designed with a certain inclination angle to prevent incoming water, as shown in Figure A-‐6.
Installation Manual | VISIX PTZ Network Camera Appendix 3 Bubble Maintenance The bubble is a transparent plastic. The dust, oil and finger print, etc. will cause scratch or image blur. Please refer to the following method to clean the bubble. 6) Handling dust Use oil free soft brush or blowing dust ball to clean the dust.
Installation Manual | VISIX PTZ Network Camera Appendix 4 RS485 Bus Connection ! General Property of RS485 Bus According to RS485 industry bus standard, RS485 is a half-‐duplex communication bus which has 120Ω characteristic impendence, the maximum load ability is 32 payloads (including controller device and controlled device).
Installation Manual | VISIX PTZ Network Camera 1# 6# 控 主 备 设 Controller Device 32# 15# Figure A-‐9 Star Shape Connection For such case, the best way is adding a RS485 distributor.
Installation Manual | VISIX PTZ Network Camera Appendix 5 24VAC Wire Gauge & Transmission Distance The following table describes the recommended max. distance adopted for the certain wire gauge when the loss rate of 24VAC voltage is less than 10%. For the AC driven device, the maximum voltage loss rate is 10% allowable.
Appendix 6 Table of Wire Gauge Standards Bare Wire Gauge(mm) American Wire Gauge AWG British Wire Gauge SWG 0.750 0.800 0.900 1.000 1.250 1.500 2.000 2.500 3.000 21 20 19 18 16 15 12 21 20 19 18 17 14 Cross-‐sectional Area of Bare Wire(mm2) 0.4417 0.5027 0.6362 0.7854 1.2266 1.