Manual

14 Settings - Relays/Alarms Tab
The Relays/Alarms tab
configures the input
alarms and associated
notifications settings for
the VIGIL Server.
Digital inputs are alarms
triggered by external cir-
cuits. The input alarm
can be used to trigger
video recording, audio
recording or PTZ events.
14.1 Input
14.1.1 Input Number
Select the Input number from the drop-down list. Click the Edit... button to rename the input for easier identification. To enable
the input, click the check box for Input Enabled.
14.1.2 Settings Tab
Configure the settings for the selected input. A Camera or Audio Channel must be selected for the Digital Input to remain enabled.
Dwell Timer The number of seconds the Digital Input remains active after a Trigger occurs.
Normal Open /
Closed
Set the normal state for the Digital Input. When the Digital Input changes state, the alarm will be trig-
gered.
Auto Acknowledge
When enabled the Alarm will be automatically acknowledged after the selected number of seconds have
passed.
Schedule Check Enabled and click ... to configure a schedule for when the Digital Input will be active.
Push Still Shot to
Server
When Enabled, a still shot from the selected camera will be uploaded to the configured server when a Digital
Input Alarm is Triggered.
Cameras Select the Camera(s) to be associated with the Digital Input.
Audio Channels Select the Audio Channel(s) to be associated with the Digital Input.