User Guide
STEP 14 : WCL02 INSTALLATION
- Power Cable Connection
2. Radiator Fan 3-pin Cable → Fan controller
3. Fan Controller 3-pin Cable → CPU Fan Terminal
1. Pump Unit 4-pin Cable → PC Power DC 12V 4pin
( Check Tube’s Bend )
전원을 켜고 2-3분간 작동상태를 점검하세요
With PC Power ON , Check Water Flow for 2~3 Minutes
Noise Control ( Use the Fan Controller )
팬콘트롤러를 조정 하세요
STEP 12 : WCL02 INSTALLATION
–Radiator Fixing
STEP 13 : WCL02 INSTALLATION
- Pump Unit Fixing
WCL02-90Cu
WCL02-120Cu
Double-faced
Adhesive Tape
CHECK LIST
2. No Trace of Leakage on Tube & Fitting (누수 점검)
3. No Overly Bent Tube, Smooth Flow (호스 꺾임 점검)
4. Secure Settling of CPU/VGA/Chipset Water Block (자켓 고정 상태 점검)
Air flow
A
i
r
f
l
o
w
From : PC Power
DC 12V
1
2
Parts
1
2
3
Parts
■ II-4. WCL02 SERIES TROUBLESHOOTING (고장 진단)
1. 연결부 재조립 (Step 1,2,3,4,5 참조)
Reassemble the parts. (Refer to Step 1,2,3,4 and 5)
2. 구입처를 통한 A/S
Contact customer service.
1. 연결부 누수 발생
Leakage in the Joint Area
2. 부품 누수
Leakage from Certain Units
누수발생
LEAKAGE
1. 호스 꺾임 조정 (Step 12 참조)
Unbend or untwist it. (Refer to Step 12.)
2. 구입처를 통한 A/S
Contact customer service.
1. 호스 꺾임
Overly Bent or Twisted Tube(s)
2. 펌프 고장
Pump Breakdown
냉각수 순환 정지
COOLANT NOT
CIRCULATING
1. 작동액 보충 (III-5항참조)
Fill the water tank up. (Refer to Section III-5)
2. 진동 방지 가이드 수정 (Step13 참조)
Refer to Step 13
1.작동액 부족
Lack of Coolant
2. 펌프 진동 발생
Vibration caused by the Pump
펌프 소음 발생
ABNORMAL PUMP NOISE
1. CPU 클립 장력 조정 (Step 11 참조)
Adjust tension on the CPU clips. (Refer to Step 11.)
2. 자켓 장착 방향 수정 (II-2 항참조)
Refer to Section II-2.
3. 냉각수흐름방향수정 (II-2 항참조)
Refer to Section II-2.
4. 라디에타 Fan 방향수정 (I-2 항참조)
Refer to Section I-2.
5. 라디에타 Fan 풍량 조정 (Step 14참조)
Adjust radiator fan RPM. (Refer to Step 14.)
6. 호스 꺾임 조정 (Step 12 참조)
Unbend or untwist it. (Refer to Step 12.)
7. 라디에타 Fan 풍량 조정 (
Step 14 참조)
Adjust radiator fan RPM. (Refer to Step 14.)
1.CPU와 자켓의 장력 부족
Insecure Mounting of the Water Block on CPU
2. 자켓 장착 방향 오류
Water Block Mounted in Wrong Direction
3. 냉각수흐름방향오류
Wrong Coolant Flow Direction
4. 라디에타 Fan 방향 오류
Radiator Fan Mounted in Wrong Direction
5. 라디에타 Fan 풍량 저하
Insufficient Air Flow by Radiator Fan
6. 호스 꺾임
Overly Bent or Twisted Tube(s)
7. 고발열 VGA Card 사용
Use of VGA Card of Excessive Heat Generation
냉각 효과 저하
LOW COOLING
PERFORMANCE
조치(SOLUTIONS)검사(POSSIBLE CAUSES)증상(SYMPTOM)
1. Secure Settling of Radiator & Pump (라디에타, 펌프 고정 상태 점검)
3
www.3rsystem.co.kr www.rbox.co.kr
반드시 제공된 볼트를 사용하여 주시기 바랍니다.
다른 볼트를 사용하면 라디에타를 손상 시킬 수 있습니다.