INSTR4089 1006 ™ Owner’s Manual This manual is for the installation, operation, and maintenance of the ScaleGard™ PLUS 2 Water Treatment Systems STM150 TSR150 Installer please leave manual with end user.
SAFETY INFORMATION Read, understand, and follow all safety information contained in these instructions prior to installation and use of the CUNO Foodservice STM150/TSR150 ScaleGard™ PLUS 2 Water Treatment Systems. Retain these instructions for future reference.
Contents Installation Requirements Space Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Feedwater Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Water Production Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Important: Installation Requirements Space Requirement 11” (27.9 cm) CAUTION To reduce the risk associated with property damage due to water leakage: • Installation must comply with existing state or local plumbing codes; • Read and follow Use Instructions before installation and use of this system. Congratulations on your purchase of the CUNO Foodservice ScaleGard™ PLUS 2 water treatment system.
ScaleGard™ PLUS 2 Installation Schematic Service Shut Off Valve (Optional) Bypass Solenoid Valve Assy. To Service Manual Bypass (Optional) Supply Water Inlet Valve 3/8" RO Water Line RO Tank RO System STM 150 Bev Plus TSR Systems Check Valve Manual Tank Valve Drain Tank Drain/Sample Valve Additional Plumbing Connections (not supplied) • Manual Bypass: A manual bypass loop is recommended to facilitate proper service of the filter system.
Installation Procedure CAUTION To reduce the risk associated with property damage due to water leakage: • Installation must comply with existing state or local plumbing codes; • Read and follow Use Instructions before installation and use of this system. Positioning Equipment Prior to installing the ScaleGard™ PLUS 2 system, review the installation schematic (page 4) and carefully plan the installation location for all system components. Obtain all additional hardware for plumbing connections.
Drain Connection The water pressure in the tank will increase as the tank fills with water. When the pressure in the tank reaches approximately 80 psi (552 kPa) the filter system shuts off. When water is drawn from the tank and the pressure drops to approximately 60 psi (414 kPa), the filter system will automatically turn on.
Start-Up Procedure 1. 2. 3. Check air pressure in the storage tank, Refer to Storage Tank Installation. (page 6) Close all water valves (5) in the system. (page 4) Open water supply valve at the connection to the main water feed and the inlet water valve at the unit. If manual bypass is installed it should be in the filter position. 4. Plug in transformer. 5. Plug bypass solenoid into the filter system. 6. Open the drain/sample valve. This will purge the air from the system.
TDS Reduction Filter (M) Replacement Procedure [annually] 1. De-pressurize the system as instructed above. 2. Locate the TDS reduction filter. To remove the TDS reduction filter, turn to the left 1/4 turn. Pull down to remove. 3. Disconnect reject tubing by pushing in the white collet on plastic fitting to release the tubing (see page 9). Discard the used cartridge. 4. Remove the plug from the plastic fitting on the new cartridge and connect the reject tubing. 5.
‘Push-In’ Tubing Connector (John Guest® Fitting) This product is outfitted with user friendly “Push In” connectors. Proper use of the connectors is shown in the diagrams. It is most important that the tubing selected for use with these connectors be of high quality, exact size and roundness, and with no surface nicks or scratches. If it is necessary to cut the tubing, use a plastic tubing cutter or sharp razor knife. Make a clean square cut.
ScaleGard™ PLUS 2 System Part List Item # STM150 TSR150-2 TSR150-4 1 Sediment Filter (S) Description 55997-01 55997-01 55997-01 2 Chlorine Reduction Filter (C) 55995-01 55995-01 55995-01 3 TDS Reduction Filter (M) 55987-07 55987-07 55987-07 4 Ion Media Filter (T) 55998-01 - - 4 Hardness Reduction Filter (H) 5 Permeate Pump 6 Pump / Fuse Assembly 53-41401 53-41401 53-41401 7 Solenoid Valve 60-1213201 60-1213201 60-1213201 8 Brine Flow Control 53-52001 53-52001 53-52
Limited Two Year Warranty CUNO Incorporated warrants the original purchaser-consumer of its Product that is free of defects in materials and workmanship. Any defect, malfunction, or other failure of the Product to conform to this warranty will be remedied by CUNO in the manner provided below. This Warranty, together with any warranties implied by law, shall be limited to a duration of two (2) years from the original date of purchase by the consumer.