Cut Sheet

3M
IMCSN Selection Chart
Product Cable Size Minimum Expanded / Cable O.D. Use Range
Number Range Maximum Recovered I.D. Maximum - Minimum
IMCSN-0400-48A 12 - 6 AWG (4 - 10 mm
2
) 0.40 / 0.15” 10,2 / 3,8 mm 0.35 - 0.15” 8,8 - 3,8 mm
IMCSN-0800-48A 8 - 3AWG (10 - 25 mm
2
) 0.80 / 0.22” 20,3 / 5,6 mm 0.70 - 0.22” 18 - 5,6 mm
IMCSN-1100-48A 2 - 2/0AWG (35 - 60 mm
2
) 1.10 / 0.37” 27,9 / 9,4 mm 0.95 - 0.37” 24 - 9,4 mm
IMCSN-1300-48A 1 - 4/0AWG (50 - 100 mm
2
) 1.30 / 0.43” 33,0 / 10,9 mm 1.10 - 0.43” 28 - 10,8 mm
IMCSN-1500-48A 1/0 - 250 kcmil (60 - 120 mm
2
) 1.50 / 0.50” 38,1 / 12,7 mm 1.30 - 0.50” 33 - 12,1 mm
IMCSN-1700-48A 4/0 - 400kcmil (120 - 200 mm
2
) 1.70 / 0.60” 43,2 / 15,2 mm 1.45 - 0.60” 37 - 15,2 mm
IMCSN-2000-48A 300 - 500kcmil (185 - 250 mm
2
) 2.00 / 0.75” 50,8 / 19,1 mm 1.75 - 0.75” 44,5 - 19,0 mm
IMCSN-3000-48A 600 - 1250 kcmil (325 - 625 mm
2
) 3.00 / 1.00” 76,2 / 25,4 mm 2.50 - 1.00” 63,5 - 25,4 mm
IMCSN-4300-48A 1000 - 2500 kcmil (625 - 1000 mm
2
) 4.30 / 1.16” 109,2 / 38,1 mm 3.60 - 1.50” 91,5 - 38,1 mm
Note: 3M IMCSN is supplied in 48-inch lengths with adhesive. Uncoated products available on special order.
Installation Techniques
Exact instructions are available on a separate sheet.
The following is a summary of the instructions.
1. Thoroughly clean and prepare cable.
2. Cut 3M IMCSN to required size, per instructions.
3. Slide 3M IMCSN tubing onto cable.
4. Install connector, if applicable.
5. Center tubing.
Property Requirement * Test Results
Corrosion
(16 hours @ 121°C)
– Copper Mirror No corrosion Pass
– Copper Contact No corrosion or pitting Pass
Flammability
(Five 15-second Bunsen
burner applications) Nonburning Pass
Water Absorption 0.5% Maximum 0.02%
(24 hours @ 25°C) weight increase
Heat Aging
(7 days @175°C)
– Ultimate Elongation 100% Minimum 225%
– Tensile Strength 1000 psi Minimum 1820 PSI
Fungus Resistance Non-nutrient Pass
Shelf Life Storage @ 40°C for 2 years
with maintenance of dimensions Pass
Performance Tests
Meets MIL-I-23053/15A Class 2.
* Based on MIL-!-23053/15AClass 2
Maintenance
3M IMCSN medium wall heat shrinkable tubing is not
impaired by freezing or overheating due to ambient
temperature found in storage or shipping. Normal
storage and stock rotation are recommended.
Availability
3M IMCSN medium wall heat shrink tubing is
available from your electrical distributor.
6. Shrink tubing from center.
7. Heat until tubing is completely shrunk and
adhesive/sealant (if applicable) is squeezed from ends.
All statements, technical information, and recommendations related
to Seller’s products are based on information believed to be reliable,
but the accuracy or completeness thereof is not guaranteed. Before
utilizing the product, the user should determine the suitability of the
product for its intended use. The user assumes all risks and liability
whatsoever in connection with such use.
Any statements or recommendations of the Seller which are not
contained in the Seller’s current publications shall have no force or
effect unless contained in an agreement signed by an authorized
officer of Seller. The statements contained herein are made in lieu of
all warranties, expressed or implied, including but not limited to the
implied warranties of merchantability and fitness for a particular
purpose which warranties are hereby expressly disclaimed.
SELLER SHALLNOTBE LIABLE TO THE USER OR ANY OTHER
PERSON UNDER ANYLEGALTHEORY, INCLUDING BUTNOT
LIMITED TO NEGLIGENCE OR STRICTLIABILITY, FOR ANY
INJURYOR FOR ANY DIRECT, INDIRECT, INCIDENTAL, OR
CONSEQUENTIALDAMAGES SUSTAINED OR INCURRED BY
REASON OF THE USE OF ANYOF THE SELLER’S PRODUCTS.
Important Notice
Litho in USA.
© 3M 1997 80-6111-0069-6
Electrical Products Division
6801 River Place Blvd.
Austin, TX 78726-9000
800/328-1368
40% Pre-consumer waste paper