Datasheet

MATERIAL SAFETY DATA SHEET 3M(TM) Screen Cleaner, #CL681 05/20/09
_________________________________________________________________________________________________
Page 4 of 7
8.2.3 Respiratory Protection
Under normal use conditions, airborne exposures are not expected to be significant enough to require respiratory protection. Avoid
breathing of vapors, mists or spray.
8.2.4 Prevention of Swallowing
Do not eat, drink or smoke when using this product. Wash exposed areas thoroughly with soap and water.
8.3 EXPOSURE GUIDELINES
Ingredient Authority Type Limit Additional Information
SODIUM HYDROXIDE ACGIH CEIL 2 mg/m3
SODIUM HYDROXIDE CMRG TWA 2 mg/m3
SODIUM HYDROXIDE OSHA CEIL 2 mg/m3 Table Z-1A
SODIUM HYDROXIDE OSHA TWA 2 mg/m3 Table Z-1
TRIETHANOLAMINE ACGIH TWA 5 mg/m3
SOURCE OF EXPOSURE LIMIT DATA:
ACGIH: American Conference of Governmental Industrial Hygienists
CMRG: Chemical Manufacturer Recommended Guideline
OSHA: Occupational Safety and Health Administration
AIHA: American Industrial Hygiene Association Workplace Environmental Exposure Level (WEEL)
SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES
Odor, Color, Grade:
Clear liquid with no odor.
General Physical Form:
Liquid
Autoignition temperature
Not Applicable
Flash Point
Not Applicable
Flammable Limits - LEL
Not Applicable
Flammable Limits - UEL
Not Applicable
Boiling point
212 ºF
Density
1 g/ml
Vapor Density
No Data Available
Vapor Pressure
18 mmHg [@ 68 ºF]
Specific Gravity
1 [Ref Std: WATER=1]
pH
7
Melting point
Not Applicable
Solubility in Water
Complete
SECTION 10: STABILITY AND REACTIVITY
Stability: Stable.