Datasheet

Description
The 3M™ Aura™ Particulate Respirator 9300+ Series provide
effective respiratory protection for use in industries where workers
will be exposed to dust particles and/or non-volatile liquid particles.
• Tested and CE Approved to EN 149:2001+A1:2009
• Foldable, easy to store, proprietary 3-panel design
accommodates facial movement for wearer comfort
• Low breathing resistance filter technology gives effective
filtration with low breathing resistance for consistent high
quality performance
• Sculpted nose panel conforms to the nose and contours of the
face and helps improve compatibility with 3M eyewear
• Innovative chin tab designed for ease of donning and
adjustment to help achieve a comfortable fit
• 3M™ Cool Flow™ exhalation valve offers improved comfort
in hot humid environments and/or where work is hard and
physical*
• Embossed top panel helps reduce fogging of eyewear
• Individual hygienic packaging helps protect the respirator from
contamination before use
• Large, soft nose foam is comfortable on the skin
• Coloured headbands for easy identification: yellow for FFP1,
blue for FFP2 and red for FFP3
Approvals
These products meet the requirements of the European Community
Directive 89/686/EEC (Personal Protective Equipment Directive)
and are thus CE marked.
Certification under Article 10, EC Type-Examination and Article
11, EC quality control, has been issued for these products by BSI,
Kitemark Court, Davy Avenue, Knowlhill Milton Keynes, MK5 8PP,
UK (Notified Body number 0086).
3M™ Aura™ Particulate Respirator
9300+ Series
Technical
Standards
These products meet the requirements of recently amended
European Standard EN 149:2001 + A1:2009, filtering facepiece
respirators for use against particles. They should be used to protect
the wearer from solid and non-volatile liquid particles only.
Products are classified by filtering efficiency and maximum total
inward leakage performance (FFP1, FFP2 and FFP3), also by
usability and clogging resistance.
Performance tests in this standard include filter penetration;
extended exposure (loading) test; flammability; breathing resistance
and total inward leakage. Reusable products are also subjected
to cleaning, storage and mandatory clogging resistance tests
(clogging is optional for non reusable products). A full copy of EN
149:2001+A1:2009 can be purchased from your national standards
body.
Designations:
R = Reusable
NR = Non reusable (single shift use only)
D = Meets the clogging resistance requirements
Applications
These respirators are suitable for use in concentrations of solid and
non-volatile liquid particles up to the following limits:
Model EN 149+A1
Classification
Exhalation
Valve
Threshold Limit Value,
TLV
9310+ FFP1 NR D Unvalved 4
9312+ FFP1 NR D Valved 4
9320+ FFP2 NR D Unvalved 12
9322+ FFP2 NR D Valved 12
9330+ FFP3 NR D Unvalved 50
9332+ FFP3 NR D Valved 50
Respiratory protection is only effective if it is correctly selected,
fitted and worn throughout the time when the wearer is exposed to
hazards.
Datasheet